B.6.4 Monitor 1, 2 and standby (MO 1212)
B.6.5 Transmitter control board (TCA 1216)
B.6.6 Remote monitoring board (RMA 1215)
Measurement Warn. limit Description
V5P OK HIGH +5 V supply voltage ok/not ok.
STS ACT HIGH A/D conversion completed ok/not ok.
DSP PFO HIGH DSP +5 V ok/not ok.
DSP ERROR LOW DSP filter conversion completed ok/not ok.
DIAG RST HIGH For resetting diag. result (not used)
SYNC ERROR LOW DSP operation ok/not ok.
V15P OK HIGH +15 V supply voltage ok/not ok.
V15N OK LOW -15 V supply voltage ok/not ok.
Measurement Warn. limit Description
EPROM PARITY CHECK LOW EPROM parity check ok/not ok.
INTEGRITY CHECK LOW Integrity check ok/not ok.
RC LINK STATUS HIGH Remote control link status ok/not ok. A
warning is generated if the TXC board does
not receive a valid data stream from the RC
unit.
INTERNAL CL DDM -1/1 (%
DDM)
Measurements on the Course CSB signal
output from the cabinet. Only measured on
hot standby systems. These signals are not
associated with the TCA 1216 board in the
automatic diagnostic functions.
INTERNAL CL SDM
36/44 (%)
See description for INTERNAL CL DDM.
INTERNAL CL RF 2.6/3.4 (V) See description for INTERNAL CL DDM.
Measurement Warn. limit Description
RMS V5P LEVEL 4.3/6 (V) +5V voltage measurement (Volt).
RMS LI BATT LEVEL 2.7/3.5 (V) Clock and RAM battery voltage measure-
ment (Volt).
EPROM CHECK HIGH Program memory CRC check ok/not ok.
Runs continuously, and completes every 30
minutes (approx.).
RAM CHECK HIGH RAM read/write test. Runs continuously,
and completes a check of all RAM every 15