Operation Manual
Table Of Contents
- 1 SYSTEM DESCRIPTION
- 1.1 System Overview
- 1.2 Abbreviations
- 2 Technical specifications
- 2.1 Signal Minimum Performance GP
- 2.2 Environmental characteristics
- 2.3 EMC characteristics
- 2.4 Mechanical characteristics
- 2.5 Power supply
- 3 Main cabinet
- 3.1 Power on/off
- 3.2 Local Control Operation
- 3.3 Local Keyboard/Display Operation
- 3.3.1 The menu structure.
- 3.3.2 Handling the different menuscreens.
- 3.3.2.1 The menu screen
- 3.3.2.2 The readout screen
- 3.3.2.3 The toggle screens
- 3.3.2.4 Input/Store screen
- 3.3.2.5 The quick read screens
- 3.3.3 The access levels.
- 3.3.3.1 Level 2
- 3.3.3.2 Level 3
- 3.3.3.3 Leaving the access levels
- 3.3.4 Function listing
- 3.3.4.1 Level 1
- 3.3.4.2 Level 2
- 3.3.4.3 Level 3
- 3.3.5 The menu tree
- 4 Tower Equipment
- 4.1 Remote Control Operation
- 4.2 Remote Slave Operation
- 4.3 Interlock Switch Operation
- 5 Remote Maintenance and Monitoring Software
- 5.1 Introduction
- 5.2 User interface components
- 5.3 Shortcuts
- 5.4 Configuring the RMM system
- 5.5 Setting up ILS stations
- 5.6 Connecting to an ILS station
- 5.7 Monitor measurements and status
- 5.8 Monitor settings
- 5.9 TX settings
- 5.10 Power scaling
- 5.11 Front panel operation
- 5.12 Get historical data
- 5.13 Continuous data logging
- 5.14 Events
- 5.15 Test DDM
- 5.16 Set ILS date/time
- 5.17 User administration
- 5.18 ILS Modem settings
- 5.19 Upload configuration to ILS
- 5.20 Write configuration to file
- 5.21 Lamp mappings
- 5.22 Medium storage sample interval
- 5.23 Displaying stored measurements
- 5.24 DIAGNOSTICS
- 5.25 Exporting data
- 5.26 Printing reports
- 5.27 Print screen
- 5.28 Technical note - Leased line SETUP (USRobotics)
- 5.29 Technical note - Dial up connection SETUP (USRobotics)
- 5.30 Technical note - Leased line SETUP (WESTERMO)
- 5.31 Technical note - dial up SETUP (WESTERMO)
- 6 Periodic maintenance CAT I and II
- 6.1 Weekly inspections
- 6.2 Monthly inspections
- 6.3 Quarterly inspections
- 6.4 Annual inspections
- 6.4.1 RF Frequency check.
- 6.4.1.1 Course Transmitter Frequency
- 6.4.1.2 Clearance Transmitter Frequency
- 6.4.2 LF Frequency check.
- 6.4.3 Transmitter waveforms checks.
- 6.4.3.1 PHASE CORR. check.
- 6.4.3.2 SBO waveform checks.
- 6.4.3.3 RF Phase
- 6.4.3.4 CSB waveform check. LF phase
- 6.4.3.5 DDM and SDM check.
- 6.4.3.6 Not in use
- 6.4.4 (Not in use)CSB output power.
- 6.4.5 Monitor Alarm Limit checks.
- 6.4.5.1 CL DDM ALARM
- 6.4.5.2 CL SDM ALARM
- 6.4.5.3 CL RF ALARM
- 6.4.5.4 DS DDM ALARM
- 6.4.5.5 NF DDM ALARM
- 6.4.5.6 CLR DDM ALARM
- 6.4.5.7 CLR SDM ALARM
- 6.4.5.8 CLR RF ALARM
- 6.4.6 Near Field Monitor delay
- 6.4.7 20 seconds inhibit
- 6.4.8 Battery maintenance
- 6.4.9 Final check GP
- 7 Corrective maintenance
- 7.1 Overview
- 7.2 Diagnostic functions
- 7.3 LRU change procedures
- 7.4 Detailed description of the automatic diagnostic algorithms
- 7.4.1 Overview
- 7.4.2 Possible diagnostic solutions
- 7.4.3 Current data diagnostics
- 7.4.3.1 I2C read error on any board implies a failure on that board
- 7.4.3.2 Maintenance parameter warnings
- 7.4.3.2.1 External power supply tests
- 7.4.3.2.2 Power supply 1 and 2 tests
- 7.4.3.2.3 Maintenance warnings without follow-errors
- 7.4.3.2.4 Power amplifier tests
- 7.4.3.2.5 Monitor 1 and 2 frontend tests
- 7.4.3.2.6 Remote control tests
- 7.4.3.2.7 Transmitter control tests
- 7.4.3.2.8 Standby monitor tests
- 7.4.3.2.9 Standby monitor frontend tests
- 7.4.3.2.10 User defined parameters
- A Monitor and Maintenance Parameters
- A.1 Monitor Alarm Parameters
- A.2 Maintenance Parameters
- B Factory default configuration settings
- B.1 Cat I monitor LIMIT configuration
- B.1.1 Description of the FFM EXE AL limits
- B.1.2 Description of the CL IDENT and CLR IDENT limits
- B.2 Cat II monitor LIMIT configuration
- B.3 Cat III monitor LIMIT configuration
- B.4 Executive Monitor delay configuration
- B.5 Maintenance parameter configuration
- B.6 Oscillator 1 and 2 (OS 1221)
- B.6.1 LF generator 1 and 2 (LF 1223)
- B.6.2 TX 1 and 2, Course and Clearance
- B.6.3 RF frontends for monitor 1, 2 and standby monitor (MF 1211/1219)
- B.6.4 Monitor 1, 2 and standby (MO 1212)
- B.6.5 Transmitter control board (TCA 1216)
- B.6.6 Remote monitoring board (RMA 1215)
- B.6.7 Power supply 1 and 2 (PS 1227)
- B.6.8 External power
- B.6.9 User defined inputs
- B.7 Maintenance delay configuration
- B.8 Morse code configuration
- B.9 Typical TX Adjustments values
- B.10 User administration configuration
- B.11 Frequency configuration strap settings
- B.11.1 OS1221B strap settings for 2-frequency GP
- C Maintenance Procedures
1DYLD$YLDWLRQ$6 )DFWRU\GHIDXOWFRQILJXUDWLRQVHWWLQJV
23(5$7,1*0$18$/1250$5&
,167580(17/$1',1*6<67(0
%
B.6.7 Power supply 1 and 2 (PS 1227)
The measurements listed here are displayed in the DC SUPPLIES maintenance window in
the RMM software.
B.6.8 External power
The measurements listed here are displayed in the DC SUPPLIES maintenance window in
the RMM software.
B.6.9 User defined inputs
No default settings are defined for these parameters.
B.7 Maintenance delay configuration
The factory default maintenance delays are as follows:
GEN delay: 20 seconds
EXT delay: 50 seconds
B.8 Morse code configuration
The factory default Morse code are “TST”.
B.9 Typical TX Adjustments values
Typical TX adjustment values lists typical values entered in the RMM software (menu item ILS
| TX settings | TX adjustments) entered in the RMM software for LLZ and GP equipment.
Measurement Warn. limit Description
V15N LEVEL -16.8/-13.8
(V)
Measurement of -15 V output voltage (Volt).
V5P LEVEL 4.6/5.9 (V) Measurement of +5 V output voltage (Volt).
V8P5P LEVEL 8.2/9.4 (V) Measurement of +8.5 V output voltage
(Volt).
V15P LEVEL 13.8/16.8 (V) Measurement of +15 V output voltage
(Volt).
Measurement Warn. limit Description
BATTERY V27P LEVEL 23/28 (V) Measurement of 27 V battery supply volt-
age.
BATTERY CURRENT -1/10 (A)
POWER CURRENT -1/20 (A)
CHARGER 1 STATUS ON Battery charger 1 status input.
CHARGER 2 STATUS ON Battery charger 2 status input.
Measurement Description
USER_DIG0 - 7 8 user definable digital inputs/output.
TEMP_OUTDOOR Analog input for outdoor temperature sensor.
TEMP_INDOOR Analog input for indoor temperature sensor.
AC_LEVEL Analog input AC power level measurement.
ANA_CH1 - 3 3 user definable analog inputs.