Operation Manual
Table Of Contents
- 1 SYSTEM DESCRIPTION
- 1.1 System Overview
- 1.2 Abbreviations
- 2 Technical specifications
- 2.1 Signal Minimum Performance GP
- 2.2 Environmental characteristics
- 2.3 EMC characteristics
- 2.4 Mechanical characteristics
- 2.5 Power supply
- 3 Main cabinet
- 3.1 Power on/off
- 3.2 Local Control Operation
- 3.3 Local Keyboard/Display Operation
- 3.3.1 The menu structure.
- 3.3.2 Handling the different menuscreens.
- 3.3.2.1 The menu screen
- 3.3.2.2 The readout screen
- 3.3.2.3 The toggle screens
- 3.3.2.4 Input/Store screen
- 3.3.2.5 The quick read screens
- 3.3.3 The access levels.
- 3.3.3.1 Level 2
- 3.3.3.2 Level 3
- 3.3.3.3 Leaving the access levels
- 3.3.4 Function listing
- 3.3.4.1 Level 1
- 3.3.4.2 Level 2
- 3.3.4.3 Level 3
- 3.3.5 The menu tree
- 4 Tower Equipment
- 4.1 Remote Control Operation
- 4.2 Remote Slave Operation
- 4.3 Interlock Switch Operation
- 5 Remote Maintenance and Monitoring Software
- 5.1 Introduction
- 5.2 User interface components
- 5.3 Shortcuts
- 5.4 Configuring the RMM system
- 5.5 Setting up ILS stations
- 5.6 Connecting to an ILS station
- 5.7 Monitor measurements and status
- 5.8 Monitor settings
- 5.9 TX settings
- 5.10 Power scaling
- 5.11 Front panel operation
- 5.12 Get historical data
- 5.13 Continuous data logging
- 5.14 Events
- 5.15 Test DDM
- 5.16 Set ILS date/time
- 5.17 User administration
- 5.18 ILS Modem settings
- 5.19 Upload configuration to ILS
- 5.20 Write configuration to file
- 5.21 Lamp mappings
- 5.22 Medium storage sample interval
- 5.23 Displaying stored measurements
- 5.24 DIAGNOSTICS
- 5.25 Exporting data
- 5.26 Printing reports
- 5.27 Print screen
- 5.28 Technical note - Leased line SETUP (USRobotics)
- 5.29 Technical note - Dial up connection SETUP (USRobotics)
- 5.30 Technical note - Leased line SETUP (WESTERMO)
- 5.31 Technical note - dial up SETUP (WESTERMO)
- 6 Periodic maintenance CAT I and II
- 6.1 Weekly inspections
- 6.2 Monthly inspections
- 6.3 Quarterly inspections
- 6.4 Annual inspections
- 6.4.1 RF Frequency check.
- 6.4.1.1 Course Transmitter Frequency
- 6.4.1.2 Clearance Transmitter Frequency
- 6.4.2 LF Frequency check.
- 6.4.3 Transmitter waveforms checks.
- 6.4.3.1 PHASE CORR. check.
- 6.4.3.2 SBO waveform checks.
- 6.4.3.3 RF Phase
- 6.4.3.4 CSB waveform check. LF phase
- 6.4.3.5 DDM and SDM check.
- 6.4.3.6 Not in use
- 6.4.4 (Not in use)CSB output power.
- 6.4.5 Monitor Alarm Limit checks.
- 6.4.5.1 CL DDM ALARM
- 6.4.5.2 CL SDM ALARM
- 6.4.5.3 CL RF ALARM
- 6.4.5.4 DS DDM ALARM
- 6.4.5.5 NF DDM ALARM
- 6.4.5.6 CLR DDM ALARM
- 6.4.5.7 CLR SDM ALARM
- 6.4.5.8 CLR RF ALARM
- 6.4.6 Near Field Monitor delay
- 6.4.7 20 seconds inhibit
- 6.4.8 Battery maintenance
- 6.4.9 Final check GP
- 7 Corrective maintenance
- 7.1 Overview
- 7.2 Diagnostic functions
- 7.3 LRU change procedures
- 7.4 Detailed description of the automatic diagnostic algorithms
- 7.4.1 Overview
- 7.4.2 Possible diagnostic solutions
- 7.4.3 Current data diagnostics
- 7.4.3.1 I2C read error on any board implies a failure on that board
- 7.4.3.2 Maintenance parameter warnings
- 7.4.3.2.1 External power supply tests
- 7.4.3.2.2 Power supply 1 and 2 tests
- 7.4.3.2.3 Maintenance warnings without follow-errors
- 7.4.3.2.4 Power amplifier tests
- 7.4.3.2.5 Monitor 1 and 2 frontend tests
- 7.4.3.2.6 Remote control tests
- 7.4.3.2.7 Transmitter control tests
- 7.4.3.2.8 Standby monitor tests
- 7.4.3.2.9 Standby monitor frontend tests
- 7.4.3.2.10 User defined parameters
- A Monitor and Maintenance Parameters
- A.1 Monitor Alarm Parameters
- A.2 Maintenance Parameters
- B Factory default configuration settings
- B.1 Cat I monitor LIMIT configuration
- B.1.1 Description of the FFM EXE AL limits
- B.1.2 Description of the CL IDENT and CLR IDENT limits
- B.2 Cat II monitor LIMIT configuration
- B.3 Cat III monitor LIMIT configuration
- B.4 Executive Monitor delay configuration
- B.5 Maintenance parameter configuration
- B.6 Oscillator 1 and 2 (OS 1221)
- B.6.1 LF generator 1 and 2 (LF 1223)
- B.6.2 TX 1 and 2, Course and Clearance
- B.6.3 RF frontends for monitor 1, 2 and standby monitor (MF 1211/1219)
- B.6.4 Monitor 1, 2 and standby (MO 1212)
- B.6.5 Transmitter control board (TCA 1216)
- B.6.6 Remote monitoring board (RMA 1215)
- B.6.7 Power supply 1 and 2 (PS 1227)
- B.6.8 External power
- B.6.9 User defined inputs
- B.7 Maintenance delay configuration
- B.8 Morse code configuration
- B.9 Typical TX Adjustments values
- B.10 User administration configuration
- B.11 Frequency configuration strap settings
- B.11.1 OS1221B strap settings for 2-frequency GP
- C Maintenance Procedures
23(5$7,1*0$18$/
1250$5&
,167580(17/$1',1*6<67(0
5HPRWH0DLQWHQDQFHDQG0RQLWRULQJ 1DYLD$YLDWLRQ$6
Table 5-13 Master user available operations.
5.17 User administration
The functionality of the ILS|User list/adm. window depends on whether or not the user is
logged in as an ordinary user or as master user. When logged in as a master user this window
allows configuring of existing and new users which shall be granted access to the RMM sys-
tem. When logged in as an ordinary user, this window only displays the last time each user
was logged on.
The following is a description of the available operations when logged in as a master user.
Figure 5-47 User administration window
The available master user operations is outlined in the table below.
Table 5-14 Master user operations.
When Edit, Add or Master is selected in the User administration window a dialog showing the
currently defined username and passwords is opened. In this dialog you may enter or change
the username and password(s).
Note that passwords must be 6-8 characters in length. Both the username and passwords
should only consist of characters in the range A-Z, a-z or 0-9.
The username for the master user cannot be changed.
Sync with PC clock (button) Sets the ILS RMS clock equal to the local PC system
clock.
Close (button) Closes the ILS date/time window.
Operation
(button)
Description
EDIT Edit the username and/or passwords for the currently selected
user
ADD Add a new user
DELETE Delete the currently selected user
MASTER Edit the passwords for the master user
DISPLAY Edit the password for the ILS front panel display panel.
Field Description