Operation Manual
Table Of Contents
- 1 SYSTEM DESCRIPTION
- 1.1 System Overview
- 1.2 Abbreviations
- 2 Technical specifications
- 2.1 Signal Minimum Performance GP
- 2.2 Environmental characteristics
- 2.3 EMC characteristics
- 2.4 Mechanical characteristics
- 2.5 Power supply
- 3 Main cabinet
- 3.1 Power on/off
- 3.2 Local Control Operation
- 3.3 Local Keyboard/Display Operation
- 3.3.1 The menu structure.
- 3.3.2 Handling the different menuscreens.
- 3.3.2.1 The menu screen
- 3.3.2.2 The readout screen
- 3.3.2.3 The toggle screens
- 3.3.2.4 Input/Store screen
- 3.3.2.5 The quick read screens
- 3.3.3 The access levels.
- 3.3.3.1 Level 2
- 3.3.3.2 Level 3
- 3.3.3.3 Leaving the access levels
- 3.3.4 Function listing
- 3.3.4.1 Level 1
- 3.3.4.2 Level 2
- 3.3.4.3 Level 3
- 3.3.5 The menu tree
- 4 Tower Equipment
- 4.1 Remote Control Operation
- 4.2 Remote Slave Operation
- 4.3 Interlock Switch Operation
- 5 Remote Maintenance and Monitoring Software
- 5.1 Introduction
- 5.2 User interface components
- 5.3 Shortcuts
- 5.4 Configuring the RMM system
- 5.5 Setting up ILS stations
- 5.6 Connecting to an ILS station
- 5.7 Monitor measurements and status
- 5.8 Monitor settings
- 5.9 TX settings
- 5.10 Power scaling
- 5.11 Front panel operation
- 5.12 Get historical data
- 5.13 Continuous data logging
- 5.14 Events
- 5.15 Test DDM
- 5.16 Set ILS date/time
- 5.17 User administration
- 5.18 ILS Modem settings
- 5.19 Upload configuration to ILS
- 5.20 Write configuration to file
- 5.21 Lamp mappings
- 5.22 Medium storage sample interval
- 5.23 Displaying stored measurements
- 5.24 DIAGNOSTICS
- 5.25 Exporting data
- 5.26 Printing reports
- 5.27 Print screen
- 5.28 Technical note - Leased line SETUP (USRobotics)
- 5.29 Technical note - Dial up connection SETUP (USRobotics)
- 5.30 Technical note - Leased line SETUP (WESTERMO)
- 5.31 Technical note - dial up SETUP (WESTERMO)
- 6 Periodic maintenance CAT I and II
- 6.1 Weekly inspections
- 6.2 Monthly inspections
- 6.3 Quarterly inspections
- 6.4 Annual inspections
- 6.4.1 RF Frequency check.
- 6.4.1.1 Course Transmitter Frequency
- 6.4.1.2 Clearance Transmitter Frequency
- 6.4.2 LF Frequency check.
- 6.4.3 Transmitter waveforms checks.
- 6.4.3.1 PHASE CORR. check.
- 6.4.3.2 SBO waveform checks.
- 6.4.3.3 RF Phase
- 6.4.3.4 CSB waveform check. LF phase
- 6.4.3.5 DDM and SDM check.
- 6.4.3.6 Not in use
- 6.4.4 (Not in use)CSB output power.
- 6.4.5 Monitor Alarm Limit checks.
- 6.4.5.1 CL DDM ALARM
- 6.4.5.2 CL SDM ALARM
- 6.4.5.3 CL RF ALARM
- 6.4.5.4 DS DDM ALARM
- 6.4.5.5 NF DDM ALARM
- 6.4.5.6 CLR DDM ALARM
- 6.4.5.7 CLR SDM ALARM
- 6.4.5.8 CLR RF ALARM
- 6.4.6 Near Field Monitor delay
- 6.4.7 20 seconds inhibit
- 6.4.8 Battery maintenance
- 6.4.9 Final check GP
- 7 Corrective maintenance
- 7.1 Overview
- 7.2 Diagnostic functions
- 7.3 LRU change procedures
- 7.4 Detailed description of the automatic diagnostic algorithms
- 7.4.1 Overview
- 7.4.2 Possible diagnostic solutions
- 7.4.3 Current data diagnostics
- 7.4.3.1 I2C read error on any board implies a failure on that board
- 7.4.3.2 Maintenance parameter warnings
- 7.4.3.2.1 External power supply tests
- 7.4.3.2.2 Power supply 1 and 2 tests
- 7.4.3.2.3 Maintenance warnings without follow-errors
- 7.4.3.2.4 Power amplifier tests
- 7.4.3.2.5 Monitor 1 and 2 frontend tests
- 7.4.3.2.6 Remote control tests
- 7.4.3.2.7 Transmitter control tests
- 7.4.3.2.8 Standby monitor tests
- 7.4.3.2.9 Standby monitor frontend tests
- 7.4.3.2.10 User defined parameters
- A Monitor and Maintenance Parameters
- A.1 Monitor Alarm Parameters
- A.2 Maintenance Parameters
- B Factory default configuration settings
- B.1 Cat I monitor LIMIT configuration
- B.1.1 Description of the FFM EXE AL limits
- B.1.2 Description of the CL IDENT and CLR IDENT limits
- B.2 Cat II monitor LIMIT configuration
- B.3 Cat III monitor LIMIT configuration
- B.4 Executive Monitor delay configuration
- B.5 Maintenance parameter configuration
- B.6 Oscillator 1 and 2 (OS 1221)
- B.6.1 LF generator 1 and 2 (LF 1223)
- B.6.2 TX 1 and 2, Course and Clearance
- B.6.3 RF frontends for monitor 1, 2 and standby monitor (MF 1211/1219)
- B.6.4 Monitor 1, 2 and standby (MO 1212)
- B.6.5 Transmitter control board (TCA 1216)
- B.6.6 Remote monitoring board (RMA 1215)
- B.6.7 Power supply 1 and 2 (PS 1227)
- B.6.8 External power
- B.6.9 User defined inputs
- B.7 Maintenance delay configuration
- B.8 Morse code configuration
- B.9 Typical TX Adjustments values
- B.10 User administration configuration
- B.11 Frequency configuration strap settings
- B.11.1 OS1221B strap settings for 2-frequency GP
- C Maintenance Procedures
1DYLD$YLDWLRQ$6 3HULRGLFPDLQWHQDQFH&$7,DQG,,
23(5$7,1*0$18$/1250$5&
,167580(17/$1',1*6<67(0
to Tx2 takes place.
a) Check that the text:
Auto ChgOver to TX2
appears in the event list.
Turn off Tx2 COU Mod 90Hz in the Modulation Switches window. Observe that the system
turns off.
b) Check that the text:
Auto ShtDown frm TX2
appears in the event list.
c) Check that measurement for PA 27V level < 1V in Maintenance Monitor Windows for
COURSE TX1 LPA/GPA and COURSE TX2 LPA/GPA.
Turn on Tx1 COU Mod 90Hz and Tx2 COU Mod 90Hz in the Modulation Switches window
again.
6.4 Annual inspections
Test Equipment
• PC including NM7000 RMM program
• NM3710 ILS Field Test Set, including attenuator 20 dB or 30 dB
• Oscilloscope
• Frequency counter 10 Hz to 350 MHz
• RF Signal generator including calibrated ILS modulation
• Digital voltmeter
• Wattmeter with probe covering 328-336MHz, 10 watts.
•Stop watch
6.4.1 RF Frequency check.
Set the
AUTOMATIC/MANUAL switch to
MANUAL
and REMOTE/LOCAL to
LOCAL.
6.4.1.1 Course Transmitter Frequency
Switch on Course Tx1.
• Connect the Frequency Counter to CSB Cou test connector in the Change Over Section
via a 50 ohm test cable. (Use 50 ohm input port of the counter)
• If necessary switch off the 90 Hz and 150 Hz modulation through the Local Display and
Keyboard or the RMM Program.
Nominal frequency: (Channel frequency + 7.5kHz) ±0.002%
Repeat the measurements for Course Tx2.
Record the frequency readings in Table 6-11.
6.4.1.2 Clearance Transmitter Frequency
Switch on Clearance Tx1.
• Connect the Frequency Counter to CSB CLR test connector in the Change Over Section
via a 50 ohm test cable. (Use 50 ohm input port of the counter)
• If necessary switch off the 90 Hz and 150 Hz modulation through the Local Display and
Keyboard or the RMM Program.