same RF level and frequency as the normal signal applied to the monitor.
Modulation shall be: Same as commisioned values DDM and SDM from CLR output of Moni-
tor network.
Verify modulation setting (DDM, SDM) by checking the test signal with the Field Test Set.
Use the Local Display and Keyboard or the RMM Program to display the measured values
for CLR DDM.
Increase DDM from the generator slowly from nominal value until a point where the letter A
(indicates that monitor has an ALARM for the displayed parameter) is shown beside the
measured parameter for Monitor 1.
Check the new generator DDM value with the Field Test Set.
Record in Table 6-14 line
f
).
Decrease DDM from the generator slowly from nominal value until a point where the letter
A (indicates that monitor has an ALARM for the displayed parameter) is shown beside the
measured parameter for Monitor 1.
Check the new generator DDM value with the Field Test Set.
Record in Table 6-14 line
ff
).
Repeat the procedure for Monitor 2.
6.4.5.7 CLR SDM ALARM
The test setup is the same as in f).
Use the Local Display and Keyboard or the RMM Program to display the measured values
for CLR SDM.
Increase SDM from the generator slowly until a point where the letter A (indicates that
monitor has an ALARM for the displayed parameter) is shown beside the measured param-
eter for Monitor 1.
Check the new generator SDM value with the Field Test Set.
Record in Table 6-14 line
g
).
Decrease SDM from the generator slowly until a point where the letter A (indicates that
monitor has an ALARM for the displayed parameter) is shown beside the measured param-
eter for Monitor 1.
Check the new generator SDM value with the Field Test Set.
Record in
Table 6-14
line
gg
).
Repeat the procedure for Monitor 2.
6.4.5.8 CLR RF ALARM
The test setup is the same as in c).
Use the Local Display and Keyboard or the RMM Program to display the measured values
for CL SDM.
Decrease slowly RF level on the generator until a point where the letter A (indicates that
monitor has an ALARM for the displayed parameter) is shown beside the measured param-
eter for Monitor 1.
The nominal level reduction should be 1 dB.
Record the RF reading at alarm point in Table 6-14 line
h
).
Repeat the procedure for Monitor 2.