Technical Handbook

Table Of Contents
1250$5&
,167580(17/$1',1*6<67(0
7(&+1,&$/+$1'%22.
'(7$,/(''(6&5,37,21  1DYLD$YLDWLRQ$6

Table 9-1 MB1203A plug in module connectors.
9.2 Tower Equipment
The following paragraphs describes the modules to be located in the control tower.
9.2.1 RCA1240C Remote Control Assembly
General Description:
The RCA1240C remote control assembly consists of the remote control RC1241A and front
panel RF1242A, and provides the user interface to the ILS Cabinet from the control tower or
technical equipment room. The RCA1240C is connected to the ILS cabinet either using ordi-
nary telephone lines or using the RS232 interface selected by jumper plugs on the RC1241A.
The telephone line interface conforms to V.21 standard (300 baud FSK) for use with ordinary
2-wire 600 ohm telephone line. The transmitter level is -10 dBm, and the receivers dynamic
range is from -10 dBm to -34 dBm.
Most of the functionality of the remote control is provided by the FPGA NMP128A described in
chapter 9.2.1.1.
Section # Module
Monitor 1
1
MO 1212A
1
MF 1211A
1
External Frontend 1
Monitor 2
1
MO 1212A
1
MF 1211A
1
External Frontend 2
Standby Monitor
1
MO 1212A
1
MF 1211A
Station Control
1
TCA 1218A
RMS
1
RMA 1215A
Transmitter 1
1
LF 1223A
1
OS 1221 A/B
Transmitter 2
1
LF 1223A
1
OS 1221A/B
Power Supply
2
PS 1227A