Technical Handbook
Table Of Contents
- 1 General Information
- 1.1 Introduction
- 1.2 Product Type Numbers
- 1.3 Abbreviations
- 2 Physical Organization
- 2.1 Module and Assembly Location
- 2.2 Service Kit Assembly
- 2.3 Power Supply
- 3 System description
- 3.1 Overview
- 3.2 Physical Description
- 3.3 Monitors
- 3.4 Transmitters / Modulators
- 3.5 TX Control
- 3.6 Remote Monitoring (RMS) Unit
- 3.7 Remote Control Unit
- 3.8 Remote Slave Panel
- 3.9 Remote Maintenance Monitoring (RMM)
- 4 Technical Specifications
- 4.1 Signal Minimum Performance GP
- 4.2 Environmental Characteristics
- 4.3 EMC Characteristics
- 4.4 Mechanical Characteristics
- 4.5 Power Supply
- 5 Mechanical Installation
- 5.1 Mounting Kit MK1343A
- 5.2 Moving RF Connectors
- 6 Electrical Installation
- 6.1 Connection Overview
- 6.2 Power and Battery
- 6.3 RF Inputs
- 6.4 RF Outputs
- 6.5 DC Loop (Localizer only)
- 6.6 Remote Control
- 6.7 PC and Modem
- 6.8 DME (localizer only)
- 6.9 For the Fernau 2020 DME the following connection is recommended
- 6.10 Analog Inputs
- 6.11 Digital Inputs and Outputs
- 6.12 Battery Warning
- 6.13 Remote control connections
- 6.14 Automatic shutdown of GP
- 6.15 Remote slave connection
- 6.16 Interlock switch connection
- 7 Tests and Adjustments
- 7.1 Configuration Settings
- 7.2 Technical note - Leased Line Setup for Remote Control (Westermo)
- 7.3 Transmitter Alignments and Calibration
- 7.3.1 RF Phase Feedback Adjustment
- 7.3.2 RF Power
- 7.3.3 LF Phase Adjustment
- 7.3.3.1 One-frequency system
- 7.3.3.2 Two-frequency system
- 7.3.4 RF Power Balance Adjustment
- 7.3.5 RF Phase at Combiner I/P
- 7.3.6 SDM Calibration
- 7.3.7 DDM Calibration
- 7.3.7.1 Test DDM Setting
- 7.3.8 Ident Tone Modulation Depth
- 7.3.8.1 Method 1
- 7.3.8.2 Method 2
- 7.3.9 RF Frequency Adjustment
- 7.4 Antenna System Adjustments
- 7.5 Monitor Alignment and Calibration.
- 7.6 Monitor Alarm Setting Procedure
- 7.7 Maintenance Limit Adjustments
- 7.8 Adjustment points
- 8 Functional Description
- 8.1 Introduction
- 8.2 Transmitter
- 8.3 Monitor
- 8.4 Transmitter Control
- 8.5 Remote control system
- 8.6 Remote Monitoring System (RMS)
- 8.7 Power Supply
- 9 Detailed description
- 9.1 Main Cabinet
- 9.1.1 MF1219A Glidepath Monitor Frontend
- 9.1.2 MO1212A Monitor
- 9.1.2.1 NMP101A Monitor Digital Frontend
- 9.1.2.2 NMP102A / NMP103A Comparator
- 9.1.3 TCA1218A Transmitter Control Assembly
- 9.1.3.1 NMP104A Station Control Monitor Data Detector
- 9.1.3.2 NMP105A Station Control Event Detection
- 9.1.3.3 NMP106A Station Control State Machine Control
- 9.1.3.4 NMP107A Terminator
- 9.1.3.5 NMP109A Remote Control Interface
- 9.1.4 LF1223A Low Frequency Generator
- 9.1.4.1 NMP110A Low Frequency Generator Control
- 9.1.5 OS1221B RF Oscillator
- 9.1.6 GPA1231A Glidepath Course Power Amplifier Assembly
- 9.1.7 GPA1232A Glidepath Clearance Power Amplifier Assembly
- 9.1.7.1 PA1234A Power Amplifier
- 9.1.7.2 AC1226A Amplitude control
- 9.1.7.3 PC1225B Phase Control
- 9.1.7.4 FD1236A Feedback Detector
- 9.1.7.5 FD1224A Feedback detector
- 9.1.7.6 CD1238A Combiner Detector
- 9.1.8 COA1207C Change-Over Assembly
- 9.1.9 PS1227A Power Supply
- 9.1.10 RMA1215A RMS Assembly
- 9.1.11 CI1210A External Connection Interface
- 9.1.12 MB1203A Monitor Section Motherboard
- 9.2 Tower Equipment
- 10 Parts Lists
- 10.1 Introduction
- 10.2 Parts Lists
- 10.3 Usable on code index
- 10.4 Figures
1250$5&
,167580(17/$1',1*6<67(0
7(&+1,&$/+$1'%22.
'(7$,/(''(6&5,37,21 1DYLD$YLDWLRQ$6
9.2.5 Slave Panel SF1344A and SP1394A
Description:
The SF1344A and SF1394A slave panel provides user interfaces to the ILS from the control
tower or equipment room. The slave panels are connected to the RCA 1240C remote control
assembly (Ch. 9.2.1) handling the interface with the ILS cabinet. SF 1344A and SF 1394A are
identical apart from mechanical dimensions.
FRONT PANEL LEDS
LEDs on the front panel indicate the ILS status (Alarm/Warning/Normal)
BUZZER
The internal buzzer provides aural alarms.
PUSHBUTTONS
Pushbutton switches provides the on/off and silence (aural alarm reset) function. The silence
button is also used for lamp test.
INTERLOCK CONNECTOR
A connector is provided for interfacing a IL 1379/IL 1380 interlock switch (Ch. 9.2.6).
9.2.6 IL1379 / IL1380 Interlock switch
Description:
The interlock switch is used if the runway has two ILS’s for opposite runway directions that
shall be interlocked.
The interlock switch consists of a key-operated change-over switch, and is connected to the
RCA1240C remote control (Ch. 9.2.1) or SF 1344A/SF1394A slave panels (Ch. 9.2.5) of the
affected localizer and glidepath equipment.
IL 1379 and IL 1380 are identical modules apart from mechanical dimensions. The IL 1379 is
3 height units by 10 length units (app. 12,8x5cm). The IL1380 is 2 height units by 9 length
units (app. 8,4x4,5cm).