Technical Handbook
Table Of Contents
- 1 General Information
- 1.1 Introduction
- 1.2 Product Type Numbers
- 1.3 Abbreviations
- 2 Physical Organization
- 2.1 Module and Assembly Location
- 2.2 Service Kit Assembly
- 2.3 Power Supply
- 3 System description
- 3.1 Overview
- 3.2 Physical Description
- 3.3 Monitors
- 3.4 Transmitters / Modulators
- 3.5 TX Control
- 3.6 Remote Monitoring (RMS) Unit
- 3.7 Remote Control Unit
- 3.8 Remote Slave Panel
- 3.9 Remote Maintenance Monitoring (RMM)
- 4 Technical Specifications
- 4.1 Signal Minimum Performance GP
- 4.2 Environmental Characteristics
- 4.3 EMC Characteristics
- 4.4 Mechanical Characteristics
- 4.5 Power Supply
- 5 Mechanical Installation
- 5.1 Mounting Kit MK1343A
- 5.2 Moving RF Connectors
- 6 Electrical Installation
- 6.1 Connection Overview
- 6.2 Power and Battery
- 6.3 RF Inputs
- 6.4 RF Outputs
- 6.5 DC Loop (Localizer only)
- 6.6 Remote Control
- 6.7 PC and Modem
- 6.8 DME (localizer only)
- 6.9 For the Fernau 2020 DME the following connection is recommended
- 6.10 Analog Inputs
- 6.11 Digital Inputs and Outputs
- 6.12 Battery Warning
- 6.13 Remote control connections
- 6.14 Automatic shutdown of GP
- 6.15 Remote slave connection
- 6.16 Interlock switch connection
- 7 Tests and Adjustments
- 7.1 Configuration Settings
- 7.2 Technical note - Leased Line Setup for Remote Control (Westermo)
- 7.3 Transmitter Alignments and Calibration
- 7.3.1 RF Phase Feedback Adjustment
- 7.3.2 RF Power
- 7.3.3 LF Phase Adjustment
- 7.3.3.1 One-frequency system
- 7.3.3.2 Two-frequency system
- 7.3.4 RF Power Balance Adjustment
- 7.3.5 RF Phase at Combiner I/P
- 7.3.6 SDM Calibration
- 7.3.7 DDM Calibration
- 7.3.7.1 Test DDM Setting
- 7.3.8 Ident Tone Modulation Depth
- 7.3.8.1 Method 1
- 7.3.8.2 Method 2
- 7.3.9 RF Frequency Adjustment
- 7.4 Antenna System Adjustments
- 7.5 Monitor Alignment and Calibration.
- 7.6 Monitor Alarm Setting Procedure
- 7.7 Maintenance Limit Adjustments
- 7.8 Adjustment points
- 8 Functional Description
- 8.1 Introduction
- 8.2 Transmitter
- 8.3 Monitor
- 8.4 Transmitter Control
- 8.5 Remote control system
- 8.6 Remote Monitoring System (RMS)
- 8.7 Power Supply
- 9 Detailed description
- 9.1 Main Cabinet
- 9.1.1 MF1219A Glidepath Monitor Frontend
- 9.1.2 MO1212A Monitor
- 9.1.2.1 NMP101A Monitor Digital Frontend
- 9.1.2.2 NMP102A / NMP103A Comparator
- 9.1.3 TCA1218A Transmitter Control Assembly
- 9.1.3.1 NMP104A Station Control Monitor Data Detector
- 9.1.3.2 NMP105A Station Control Event Detection
- 9.1.3.3 NMP106A Station Control State Machine Control
- 9.1.3.4 NMP107A Terminator
- 9.1.3.5 NMP109A Remote Control Interface
- 9.1.4 LF1223A Low Frequency Generator
- 9.1.4.1 NMP110A Low Frequency Generator Control
- 9.1.5 OS1221B RF Oscillator
- 9.1.6 GPA1231A Glidepath Course Power Amplifier Assembly
- 9.1.7 GPA1232A Glidepath Clearance Power Amplifier Assembly
- 9.1.7.1 PA1234A Power Amplifier
- 9.1.7.2 AC1226A Amplitude control
- 9.1.7.3 PC1225B Phase Control
- 9.1.7.4 FD1236A Feedback Detector
- 9.1.7.5 FD1224A Feedback detector
- 9.1.7.6 CD1238A Combiner Detector
- 9.1.8 COA1207C Change-Over Assembly
- 9.1.9 PS1227A Power Supply
- 9.1.10 RMA1215A RMS Assembly
- 9.1.11 CI1210A External Connection Interface
- 9.1.12 MB1203A Monitor Section Motherboard
- 9.2 Tower Equipment
- 10 Parts Lists
- 10.1 Introduction
- 10.2 Parts Lists
- 10.3 Usable on code index
- 10.4 Figures
1250$5&
,167580(17/$1',1*6<67(0
7(&+1,&$/+$1'%22.
7(676$1'$'-8670(176 1DYLD$YLDWLRQ$6
Figure 7-1 Station Control strap platform.
7.1.2 Remote Ports Access Level Configuration
The allowed access levels on REMOTE ports 1 and 2 on the RMS can be configured by set-
ting jumpers S1-S4 on the Transmitter Control Assembly TCA1218A (Figure 7-1) according to
Table 7-1 .
Jumper in means that access level is allowed.
Jumper out means that access level is denied.
Table 7-2 Access level strap settings.
7.1.3 Warning Configuration
Use the RMM Program to configure which warnings shall cause system warning i.e. illuminate
the RC main warning lamp.
7.1.4 Remote Control Interface (CI 1210)
The transmission medium (telephone line (FSK modem) or RS 232) to the Remote Control
can be selected by plugs and link straps S9 - S14 on the Connection Interface CI 1210 if the
equipment is equipped with the RS-232 cable
Table 7-3 Remote Control Setup
PORT ACC. LEVEL 2 ACC. LEVEL 3
Remote 1 Strap S1 Strap S2
Remote 2 Strap S3 Strap S4
Straps in Function Connector used
S9, S10, S11 Telephone line (FSK
modem)
CI 1210, P29
S12, S13, S14* RS-232 9 pin DSUB below CI 1210
1
2
3
4
5
6
7
8
9
10
HBK592-1