7(676$1'$'-8670(176  1DYLD$YLDWLRQ$6

Figure 7-1 Station Control strap platform.
7.1.2 Remote Ports Access Level Configuration
The allowed access levels on REMOTE ports 1 and 2 on the RMS can be configured by set-
ting jumpers S1-S4 on the Transmitter Control Assembly TCA1218A (Figure 7-1) according to
Table 7-1 .
Jumper in means that access level is allowed.
Jumper out means that access level is denied.
Table 7-2 Access level strap settings.
7.1.3 Warning Configuration
Use the RMM Program to configure which warnings shall cause system warning i.e. illuminate
the RC main warning lamp.
7.1.4 Remote Control Interface (CI 1210)
The transmission medium (telephone line (FSK modem) or RS 232) to the Remote Control
can be selected by plugs and link straps S9 - S14 on the Connection Interface CI 1210 if the
equipment is equipped with the RS-232 cable
Table 7-3 Remote Control Setup
PORT ACC. LEVEL 2 ACC. LEVEL 3
Remote 1 Strap S1 Strap S2
Remote 2 Strap S3 Strap S4
Straps in Function Connector used
S9, S10, S11 Telephone line (FSK
modem)
CI 1210, P29
S12, S13, S14* RS-232 9 pin DSUB below CI 1210