Table 7-10 Glidepath alarm limits
* Only for single frequency ILS. For two frequency ILS the limit is +/- 1dB.
CLR transmitter is only present in two frequency ILS.
7.7 Maintenance Limit Adjustments
Use the RMM Program to set maintenance warning limits in the system. All new systems will
have factory preset maintenance warning limits. Maintenance warning limits can not be set
from the Local Display/Keyboard.
CL DS NF CLR
GP CAT1 DDM 30uA 37uA 30uA 45uA
SDM ± 5% ------ ------ ± 5%
RF level ± 3dB* ------ ------ ± 1dB
CAT II DDM 30uA 37uA 30uA 45uA
SDM ± 5% ------ ------ ± 5%
RF level ± 3dB* ------ ------ ± 1dB
CATIII DDM 30uA 37uA 30uA 45uA
SDM ± 5% ------ ------ ± 5%
RF level ± 3dB* ------ ------ ± 1dB