Technical Handbook
Table Of Contents
- 1 General Information
- 1.1 Introduction
- 1.2 Product Type Numbers
- 1.3 Abbreviations
- 2 Physical Organization
- 2.1 Module and Assembly Location
- 2.2 Service Kit Assembly
- 2.3 Power Supply
- 3 System description
- 3.1 Overview
- 3.2 Physical Description
- 3.3 Monitors
- 3.4 Transmitters / Modulators
- 3.5 TX Control
- 3.6 Remote Monitoring (RMS) Unit
- 3.7 Remote Control Unit
- 3.8 Remote Slave Panel
- 3.9 Remote Maintenance Monitoring (RMM)
- 4 Technical Specifications
- 4.1 Signal Minimum Performance GP
- 4.2 Environmental Characteristics
- 4.3 EMC Characteristics
- 4.4 Mechanical Characteristics
- 4.5 Power Supply
- 5 Mechanical Installation
- 5.1 Mounting Kit MK1343A
- 5.2 Moving RF Connectors
- 6 Electrical Installation
- 6.1 Connection Overview
- 6.2 Power and Battery
- 6.3 RF Inputs
- 6.4 RF Outputs
- 6.5 DC Loop (Localizer only)
- 6.6 Remote Control
- 6.7 PC and Modem
- 6.8 DME (localizer only)
- 6.9 For the Fernau 2020 DME the following connection is recommended
- 6.10 Analog Inputs
- 6.11 Digital Inputs and Outputs
- 6.12 Battery Warning
- 6.13 Remote control connections
- 6.14 Automatic shutdown of GP
- 6.15 Remote slave connection
- 6.16 Interlock switch connection
- 7 Tests and Adjustments
- 7.1 Configuration Settings
- 7.2 Technical note - Leased Line Setup for Remote Control (Westermo)
- 7.3 Transmitter Alignments and Calibration
- 7.3.1 RF Phase Feedback Adjustment
- 7.3.2 RF Power
- 7.3.3 LF Phase Adjustment
- 7.3.3.1 One-frequency system
- 7.3.3.2 Two-frequency system
- 7.3.4 RF Power Balance Adjustment
- 7.3.5 RF Phase at Combiner I/P
- 7.3.6 SDM Calibration
- 7.3.7 DDM Calibration
- 7.3.7.1 Test DDM Setting
- 7.3.8 Ident Tone Modulation Depth
- 7.3.8.1 Method 1
- 7.3.8.2 Method 2
- 7.3.9 RF Frequency Adjustment
- 7.4 Antenna System Adjustments
- 7.5 Monitor Alignment and Calibration.
- 7.6 Monitor Alarm Setting Procedure
- 7.7 Maintenance Limit Adjustments
- 7.8 Adjustment points
- 8 Functional Description
- 8.1 Introduction
- 8.2 Transmitter
- 8.3 Monitor
- 8.4 Transmitter Control
- 8.5 Remote control system
- 8.6 Remote Monitoring System (RMS)
- 8.7 Power Supply
- 9 Detailed description
- 9.1 Main Cabinet
- 9.1.1 MF1219A Glidepath Monitor Frontend
- 9.1.2 MO1212A Monitor
- 9.1.2.1 NMP101A Monitor Digital Frontend
- 9.1.2.2 NMP102A / NMP103A Comparator
- 9.1.3 TCA1218A Transmitter Control Assembly
- 9.1.3.1 NMP104A Station Control Monitor Data Detector
- 9.1.3.2 NMP105A Station Control Event Detection
- 9.1.3.3 NMP106A Station Control State Machine Control
- 9.1.3.4 NMP107A Terminator
- 9.1.3.5 NMP109A Remote Control Interface
- 9.1.4 LF1223A Low Frequency Generator
- 9.1.4.1 NMP110A Low Frequency Generator Control
- 9.1.5 OS1221B RF Oscillator
- 9.1.6 GPA1231A Glidepath Course Power Amplifier Assembly
- 9.1.7 GPA1232A Glidepath Clearance Power Amplifier Assembly
- 9.1.7.1 PA1234A Power Amplifier
- 9.1.7.2 AC1226A Amplitude control
- 9.1.7.3 PC1225B Phase Control
- 9.1.7.4 FD1236A Feedback Detector
- 9.1.7.5 FD1224A Feedback detector
- 9.1.7.6 CD1238A Combiner Detector
- 9.1.8 COA1207C Change-Over Assembly
- 9.1.9 PS1227A Power Supply
- 9.1.10 RMA1215A RMS Assembly
- 9.1.11 CI1210A External Connection Interface
- 9.1.12 MB1203A Monitor Section Motherboard
- 9.2 Tower Equipment
- 10 Parts Lists
- 10.1 Introduction
- 10.2 Parts Lists
- 10.3 Usable on code index
- 10.4 Figures
)81&7,21$/'(6&5,37,21
1250$5&
1DYLD$YLDWLRQ$6
,167580(17/$1',1*6<67(0
7(&+1,&$/+$1'%22.
Figure 8-8 The IIC serial bus and ADC channels.
8.7 Power Supply
The ILS main cabinet is supplied from one or two 27V power supplies with a backup battery.
The 27V is regulated down to
±
15V, 8.5V and 5V. The transmitter power amplifiers are fed
directly from the 27V supply, while the rest of the system uses the regulated voltages.
Current measurements are done on the power supply, the battery and each power amplifier.
Each regulated voltage is measured in the Power Supply PS1227A. The results are presented
to the user through the RMS system.
When the ILS signals are shut down, the power supply to the power amplifiers are actually
turned off by relays. This is controlled by the
terminator alarm
signal from the station control
section.
The backup battery is protected against deep discharge with a protection circuit. This circuit
disconnects the battery when the voltage drops below 22V.
A battery warning is given through the RMS system when the primary power supply (supplies)
fails.
RMA 1215A
MF 1219A
MON1
MF 1219A
MON2
MO 1212A
MON1
MO 1212A
MON2
PS 1227A #1 PS 1227A #2
LF 1223A
TX1
LF 1223A
TX1
GPA 1231A
TX1 COU
GPA 1232A
TX1 CLR
GPA 1231A
TX2 COU
GPA 1232A
TX2 CLR
CI 1210A
IIC serial
bus
ADC
channels
MF 1219A
STB MON
MO 1212A
STB MON
OS 1221B
TX1
OS 1221B
TX2
HBK571-1