Technical Handbook
Table Of Contents
- 1 General Information
- 1.1 Introduction
- 1.2 Product Type Numbers
- 1.3 Abbreviations
- 2 Physical Organization
- 2.1 Module and Assembly Location
- 2.2 Service Kit Assembly
- 2.3 Power Supply
- 3 System description
- 3.1 Overview
- 3.2 Physical Description
- 3.3 Monitors
- 3.4 Transmitters / Modulators
- 3.5 TX Control
- 3.6 Remote Monitoring (RMS) Unit
- 3.7 Remote Control Unit
- 3.8 Remote Slave Panel
- 3.9 Remote Maintenance Monitoring (RMM)
- 4 Technical Specifications
- 4.1 Signal Minimum Performance GP
- 4.2 Environmental Characteristics
- 4.3 EMC Characteristics
- 4.4 Mechanical Characteristics
- 4.5 Power Supply
- 5 Mechanical Installation
- 5.1 Mounting Kit MK1343A
- 5.2 Moving RF Connectors
- 6 Electrical Installation
- 6.1 Connection Overview
- 6.2 Power and Battery
- 6.3 RF Inputs
- 6.4 RF Outputs
- 6.5 DC Loop (Localizer only)
- 6.6 Remote Control
- 6.7 PC and Modem
- 6.8 DME (localizer only)
- 6.9 For the Fernau 2020 DME the following connection is recommended
- 6.10 Analog Inputs
- 6.11 Digital Inputs and Outputs
- 6.12 Battery Warning
- 6.13 Remote control connections
- 6.14 Automatic shutdown of GP
- 6.15 Remote slave connection
- 6.16 Interlock switch connection
- 7 Tests and Adjustments
- 7.1 Configuration Settings
- 7.2 Technical note - Leased Line Setup for Remote Control (Westermo)
- 7.3 Transmitter Alignments and Calibration
- 7.3.1 RF Phase Feedback Adjustment
- 7.3.2 RF Power
- 7.3.3 LF Phase Adjustment
- 7.3.3.1 One-frequency system
- 7.3.3.2 Two-frequency system
- 7.3.4 RF Power Balance Adjustment
- 7.3.5 RF Phase at Combiner I/P
- 7.3.6 SDM Calibration
- 7.3.7 DDM Calibration
- 7.3.7.1 Test DDM Setting
- 7.3.8 Ident Tone Modulation Depth
- 7.3.8.1 Method 1
- 7.3.8.2 Method 2
- 7.3.9 RF Frequency Adjustment
- 7.4 Antenna System Adjustments
- 7.5 Monitor Alignment and Calibration.
- 7.6 Monitor Alarm Setting Procedure
- 7.7 Maintenance Limit Adjustments
- 7.8 Adjustment points
- 8 Functional Description
- 8.1 Introduction
- 8.2 Transmitter
- 8.3 Monitor
- 8.4 Transmitter Control
- 8.5 Remote control system
- 8.6 Remote Monitoring System (RMS)
- 8.7 Power Supply
- 9 Detailed description
- 9.1 Main Cabinet
- 9.1.1 MF1219A Glidepath Monitor Frontend
- 9.1.2 MO1212A Monitor
- 9.1.2.1 NMP101A Monitor Digital Frontend
- 9.1.2.2 NMP102A / NMP103A Comparator
- 9.1.3 TCA1218A Transmitter Control Assembly
- 9.1.3.1 NMP104A Station Control Monitor Data Detector
- 9.1.3.2 NMP105A Station Control Event Detection
- 9.1.3.3 NMP106A Station Control State Machine Control
- 9.1.3.4 NMP107A Terminator
- 9.1.3.5 NMP109A Remote Control Interface
- 9.1.4 LF1223A Low Frequency Generator
- 9.1.4.1 NMP110A Low Frequency Generator Control
- 9.1.5 OS1221B RF Oscillator
- 9.1.6 GPA1231A Glidepath Course Power Amplifier Assembly
- 9.1.7 GPA1232A Glidepath Clearance Power Amplifier Assembly
- 9.1.7.1 PA1234A Power Amplifier
- 9.1.7.2 AC1226A Amplitude control
- 9.1.7.3 PC1225B Phase Control
- 9.1.7.4 FD1236A Feedback Detector
- 9.1.7.5 FD1224A Feedback detector
- 9.1.7.6 CD1238A Combiner Detector
- 9.1.8 COA1207C Change-Over Assembly
- 9.1.9 PS1227A Power Supply
- 9.1.10 RMA1215A RMS Assembly
- 9.1.11 CI1210A External Connection Interface
- 9.1.12 MB1203A Monitor Section Motherboard
- 9.2 Tower Equipment
- 10 Parts Lists
- 10.1 Introduction
- 10.2 Parts Lists
- 10.3 Usable on code index
- 10.4 Figures
1250$5&
,167580(17/$1',1*6<67(0
7(&+1,&$/+$1'%22.
'(7$,/(''(6&5,37,21 1DYLD$YLDWLRQ$6
Block Description:
STB LAMP FILTER
This block provides the standby lamp information to be sent to remote control by the TX
UART.
TX UART
Converts parallel data to 2-bytes serial messages. Protocol for the serial data SDOUT (sent I
1210A) is startbit, 8 databits, 1 stopbit, odd parity.
RX UART
Converts serial data SDIN received from remote control (via CI 1210A) to parallel data (2
bytes).
MESSAGE DETECTOR
Messages from RX UART are accepted only if two idnetical messages are received in
sequence. If so, the data output latch is updated and a new-message pulse is generated.
NEW MESSAGE TIMER
Checks whether an OK message from MESSAGE DETECTOR and carrier detect signal from
CI 1210A is present. Missing message or no carrier detect for 2 seconds or more gives time-
out signal to DATA FILTER.
DATA FILTER
In case the NEW MESSAGE TIMER has signalled a timeout (indicating missing messages)
this block will modify the data received from the MESSAGE DETECTOR by forcing the
TX_OFF signal to on (configurable). If configuration enables interlock, the interlock signal is
also forced active.