User's Manual
Table Of Contents
- part i INTRODUCTION
- 1 GENERAL INFORMATION
- 1.1 Introduction
- 1.2 Product Type Numbers
- 1.3 Abbreviations
- 2 Physical organisation
- 2.1 Configurations
- 3 System Description
- 3.1 Introduction / Overview
- 3.2 Transmitters / Modulators
- 3.3 Monitors / Transmitter Control
- 3.4 Power Systems
- 3.5 Remote control system
- 3.6 Remote Maintenance Monitoring (RMM)
- 3.7 RMM Access
- 3.8 Storage Functions
- 3.9 Local Keyboard/Display Functions
- 3.10 Diagnostic functions
- 3.11 Document structure
- 4 Technical Specifications
- 4.1 Signal Requirements
- 4.2 Environmental characteristics
- 4.3 EMV-charakteristics
- 4.4 Mechanical characteristics
- 4.5 Power supply
- PART II instalLation
- 5 Mechanical Installation
- 5.1 Marker beacon Cabinet
- 5.2 Remote control
- 5.3 Antenna
- 6 Electrical installation
- 6.1 Marker beacon cabinet
- 6.2 Tower equipment
- 6.3 System Installation
- 7 Tests and adjustments
- 7.1 Preparations
- 7.2 Configuration settings
- 7.3 Adjustment points
- 7.4 Adjustments at installation
- 7.5 Other adjustments
- PART III Operation
- 8 Operation Main Cabinet
- 8.1 Power On/off
- 8.2 Local Control Operation
- 8.3 Local Keyboard/display Operation
- 8.3.1 The menu structure
- 8.3.2 Handling the different menu screens.
- 8.3.2.1 The menu screen
- 8.3.2.2 The readout screen
- 8.3.2.3 The toggle screens
- 8.3.2.4 Input/Store screen
- 8.3.2.5 The quick read screen
- 8.3.3 The access levels
- 8.3.3.1 Level 2
- 8.3.3.2 Level 3
- 8.3.3.3 Leaving the access levels
- 8.3.4 Function listing
- 8.3.4.1 Level 1
- 8.3.4.2 Level 2
- 8.3.4.3 Level 3
- 8.3.5 The menu tree
- 9 Remote Control And Slave Operation
- 9.1 Remote Control Operation
- 9.2 Slave Panel Operation
- 10 Operation of RMM
- 10.1 Introduction
- 10.2 The desktop area
- 10.3 Installation
- 10.4 Getting started
- 10.5 Users guide
- 10.5.1 The menus
- 10.5.2 The toolbar
- 10.5.3 Logging in and out and access levels
- 10.5.4 Station list
- 10.5.5 Modem set-up
- 10.5.6 Setting up connections
- 10.5.6.1 Setting up a Dial-up connection with an US Robotics Courier V34 modem
- 10.5.6.2 Setting up a Dial-Up connection with a Westermo modem
- 10.5.6.3 Setting up a leased-line connection with a US Robotics Courier V34 modem
- 10.5.6.4 Setting up a leased-line connection with a Westermo modem
- 10.5.7 Front panel
- 10.5.8 Monitor windows
- 10.5.9 Maintenance
- 10.5.9.1 Description of maintenance parameters
- 10.5.10 TX settings
- 10.5.11 Event list
- 10.5.12 Delays
- 10.5.13 Printing Reports
- 10.5.14 Loading and saving alarm/warning limits and delays
- 10.5.15 Tool options
- 10.5.15.1 The Data Logging Page
- 10.5.15.2 The NM7050 Options page
- 10.5.15.3 The NM7050 Main Warning mapping page
- 10.5.15.4 The NM7050 Communications page
- 10.5.16 Administration
- 11 Periodic maintenance
- 11.1 Reference Report
- 11.2 Monthly inspection
- 11.3 Annual inspection
- PART IV description
- 12 Detailed Description
- 12.1 Main Cabinet
- 12.1.1 TX 1373A Transmitter
- 12.1.1.1 General Description
- 12.1.1.2 Block diagram
- 12.1.1.3 Signals
- 12.1.1.4 Building blocks
- 12.1.2 MO1374 Monitor
- 12.1.2.1 General description
- 12.1.2.2 Block diagram
- 12.1.2.3 Signals
- 12.1.2.4 Building blocks
- 12.1.3 PS1375 Power Supply Module Description
- 12.1.3.1 General description
- 12.1.3.2 Block diagram
- 12.1.3.3 Signals
- 12.1.3.4 Functional description
- 12.1.4 CI1376/PB1378 Connection Interface Module Description
- 12.1.4.1 General description
- 12.1.4.2 Block diagram
- 12.1.4.3 Signals
- 12.1.4.4 Building Blocks
- 12.1.5 LC 1377 Local Control and Display/Keyboard Interface
- 12.1.5.1 General description
- 12.1.5.2 Block Diagram
- 12.1.5.3 Signals
- 12.1.5.4 Building Blocks
- 12.2 Tower Equipment
- 12.2.1 Remote Control Assembly
- 12.2.1.1 General Description
- 12.2.1.2 Block Diagram
- 12.2.1.3 Signals
- 12.2.1.4 Block Description
- 12.2.1.5 General Description
- 12.2.1.6 Block Diagram
- 12.2.1.7 Block Description
- 12.2.2 Remote Frame Assembly - RFA1353
- 12.2.3 SF1344 / SP 1394 Remote Slave Panel
- 12.2.3.1 General Description
- 12.2.3.2 Block Diagram
- 12.2.3.3 Signals
- 12.2.3.4 Block Description
- 12.3 Antenna
- 13 Circuit diagrams
- 14 Parts lists
- 15 Component Locations
- PART V APPENDIX
- A ANTENNA TYPE NM 3561 / NM 3562
- A.1 Antenna NM 3561 / NM 3562 For Ils Marker Beacon
- B MAINTENANCE PARAMETERS
- C CUSTOMERS INFORMATION
©1999 Navia Aviation AS 21464-5 Operation of RMM
USER MANUALNORMARC 7050
MARKER BEACON
10-35
Figure 10-34 The Setup Select View
Select which parts of the setup you actually want to load. By default everything is selected.
When selection is satisfactory, press the Load Settings button. The progress bar in the top of
the view will now increase until all parameters/delays are properly set. This may take some
time, especially for the maintenance settings, so be patient.
You must have access level 3 or higher to be able to load settings from file.
10.5.15 Tool options
From Tool Options the secondary parameters and facilities are configured. The options are
organised in different pages that are accessed through selecting the different tabs in the dia-
logue. Note that the settings you specify are directly executed when selecting an A
PPLY button
in one of the option pages. The C
ANCEL button will not redo these changes.
10.5.15.1The Data Logging Page
From the Data Logging page you may specify regular logging of data to hard disk files. Log-
ging of Maintenance and Monitor data is done to separate files.