User's Manual

Table Of Contents
USER MANUAL
4-2
21464-5
NORMARC 7050
MARKER BEACON
Technical Specifications ©1999 Navia Aviation AS
4.1.3 Monitoring
4.1.3.1 Alarm Functions
4.1.3.2 Monitor input levels
4.1.3.3 Monitor stability at nominal levels
4.1.3.4 Warning funktion
4.1.3.5 Protocols
4.1.4 Remote Control
RF power reduction
1,5-3
DB adjustable
Change of modulation depth
50-70 %
Depth of Modulation
Keying absence
Alarm identification to automatic
transmitter change over
S
ENDERUMSCHALTUNG
2-5 sec.
LINE BREAK MB - Remote Control
(
DISABLE OPTIONAL) Standby alarm identification
to transmitter shutdown shall be configurable.
Adjustment range, nominal level
+1 TO -25
DBM (strap settings for IM, MM
and OM sensitivity)
RF POWER VALUES ±0,5 DB
M
ODULATION DEPTH VALUES
±1,0 % Depth of Modulation
@ 10 – 30 ºC
±3,0 %
Depth of Modulation
@ full temp. range
±2,0 %
Depth of Modulation
variation for 3dB RF
reduction @ 10-30°C.
RF
POWER REDUCTION
40-75 % of alarm limit
Change of modulation depth
40-75 %
of alarm limit
Maintenance parameter outside limits
Mains failure
Monitor 1 to monitor 2 communication S
ERIAL DATA PROTOCOL (not RS 232)
RMM
DATA PROTOCOL RS232
Either