User's Manual

Table Of Contents
USER MANUAL
7-4
21464-5
NORMARC 7050
MARKER BEACON
Tests and adjustments ©1999 Navia Aviation AS
7.2.4 Remote Control configuration
The Aural Alarm / Warning functions and transmission medium (telephone line or RS 232) in
the Remote Control can be selected by link straps:
The strap links S6 to S12 will give Aural Warning for the following warning parameters when
connected::
Warning reset (Silence):
Buzzer:
Telephone Line / RS 232 / TTL logic:
S700 pins con-
nected
S701 pins con-
nected
Function
1-2 1-2 RS 232
3-4 3-4 Telephone line
Strap Warning Parameter
S6 Standby Alarm (Hot Standby racks only)
S7 Parameter Warning
S8 Ident Warning
S9 Battery Warning
S10 Standby on Air
S11 Monitor Disagree Warning
S12 Maintenance Warning
Strap Function
S1 in Silence on Remote Control resets Remote Control buzzer
only
S1 out Silence on Remote Control resets both Remote Control
and Slave Panel buzzer
S5 in Silence on Slave Panel resets Slave Panel buzzer only
S5 out Silence on Slave Panel resets both Remote Control and
Slave Panel buzzer
Strap Function
S4 in Buzzer connected
S4 out Buzzer disconnected