User's Manual
Table Of Contents
- part i INTRODUCTION
- 1 GENERAL INFORMATION
- 1.1 Introduction
- 1.2 Product Type Numbers
- 1.3 Abbreviations
- 2 Physical organisation
- 2.1 Configurations
- 3 System Description
- 3.1 Introduction / Overview
- 3.2 Transmitters / Modulators
- 3.3 Monitors / Transmitter Control
- 3.4 Power Systems
- 3.5 Remote control system
- 3.6 Remote Maintenance Monitoring (RMM)
- 3.7 RMM Access
- 3.8 Storage Functions
- 3.9 Local Keyboard/Display Functions
- 3.10 Diagnostic functions
- 3.11 Document structure
- 4 Technical Specifications
- 4.1 Signal Requirements
- 4.2 Environmental characteristics
- 4.3 EMV-charakteristics
- 4.4 Mechanical characteristics
- 4.5 Power supply
- PART II instalLation
- 5 Mechanical Installation
- 5.1 Marker beacon Cabinet
- 5.2 Remote control
- 5.3 Antenna
- 6 Electrical installation
- 6.1 Marker beacon cabinet
- 6.2 Tower equipment
- 6.3 System Installation
- 7 Tests and adjustments
- 7.1 Preparations
- 7.2 Configuration settings
- 7.3 Adjustment points
- 7.4 Adjustments at installation
- 7.5 Other adjustments
- PART III Operation
- 8 Operation Main Cabinet
- 8.1 Power On/off
- 8.2 Local Control Operation
- 8.3 Local Keyboard/display Operation
- 8.3.1 The menu structure
- 8.3.2 Handling the different menu screens.
- 8.3.2.1 The menu screen
- 8.3.2.2 The readout screen
- 8.3.2.3 The toggle screens
- 8.3.2.4 Input/Store screen
- 8.3.2.5 The quick read screen
- 8.3.3 The access levels
- 8.3.3.1 Level 2
- 8.3.3.2 Level 3
- 8.3.3.3 Leaving the access levels
- 8.3.4 Function listing
- 8.3.4.1 Level 1
- 8.3.4.2 Level 2
- 8.3.4.3 Level 3
- 8.3.5 The menu tree
- 9 Remote Control And Slave Operation
- 9.1 Remote Control Operation
- 9.2 Slave Panel Operation
- 10 Operation of RMM
- 10.1 Introduction
- 10.2 The desktop area
- 10.3 Installation
- 10.4 Getting started
- 10.5 Users guide
- 10.5.1 The menus
- 10.5.2 The toolbar
- 10.5.3 Logging in and out and access levels
- 10.5.4 Station list
- 10.5.5 Modem set-up
- 10.5.6 Setting up connections
- 10.5.6.1 Setting up a Dial-up connection with an US Robotics Courier V34 modem
- 10.5.6.2 Setting up a Dial-Up connection with a Westermo modem
- 10.5.6.3 Setting up a leased-line connection with a US Robotics Courier V34 modem
- 10.5.6.4 Setting up a leased-line connection with a Westermo modem
- 10.5.7 Front panel
- 10.5.8 Monitor windows
- 10.5.9 Maintenance
- 10.5.9.1 Description of maintenance parameters
- 10.5.10 TX settings
- 10.5.11 Event list
- 10.5.12 Delays
- 10.5.13 Printing Reports
- 10.5.14 Loading and saving alarm/warning limits and delays
- 10.5.15 Tool options
- 10.5.15.1 The Data Logging Page
- 10.5.15.2 The NM7050 Options page
- 10.5.15.3 The NM7050 Main Warning mapping page
- 10.5.15.4 The NM7050 Communications page
- 10.5.16 Administration
- 11 Periodic maintenance
- 11.1 Reference Report
- 11.2 Monthly inspection
- 11.3 Annual inspection
- PART IV description
- 12 Detailed Description
- 12.1 Main Cabinet
- 12.1.1 TX 1373A Transmitter
- 12.1.1.1 General Description
- 12.1.1.2 Block diagram
- 12.1.1.3 Signals
- 12.1.1.4 Building blocks
- 12.1.2 MO1374 Monitor
- 12.1.2.1 General description
- 12.1.2.2 Block diagram
- 12.1.2.3 Signals
- 12.1.2.4 Building blocks
- 12.1.3 PS1375 Power Supply Module Description
- 12.1.3.1 General description
- 12.1.3.2 Block diagram
- 12.1.3.3 Signals
- 12.1.3.4 Functional description
- 12.1.4 CI1376/PB1378 Connection Interface Module Description
- 12.1.4.1 General description
- 12.1.4.2 Block diagram
- 12.1.4.3 Signals
- 12.1.4.4 Building Blocks
- 12.1.5 LC 1377 Local Control and Display/Keyboard Interface
- 12.1.5.1 General description
- 12.1.5.2 Block Diagram
- 12.1.5.3 Signals
- 12.1.5.4 Building Blocks
- 12.2 Tower Equipment
- 12.2.1 Remote Control Assembly
- 12.2.1.1 General Description
- 12.2.1.2 Block Diagram
- 12.2.1.3 Signals
- 12.2.1.4 Block Description
- 12.2.1.5 General Description
- 12.2.1.6 Block Diagram
- 12.2.1.7 Block Description
- 12.2.2 Remote Frame Assembly - RFA1353
- 12.2.3 SF1344 / SP 1394 Remote Slave Panel
- 12.2.3.1 General Description
- 12.2.3.2 Block Diagram
- 12.2.3.3 Signals
- 12.2.3.4 Block Description
- 12.3 Antenna
- 13 Circuit diagrams
- 14 Parts lists
- 15 Component Locations
- PART V APPENDIX
- A ANTENNA TYPE NM 3561 / NM 3562
- A.1 Antenna NM 3561 / NM 3562 For Ils Marker Beacon
- B MAINTENANCE PARAMETERS
- C CUSTOMERS INFORMATION
©1999 Navia Aviation AS 21464-5 Operation of RMM
USER MANUALNORMARC 7050
MARKER BEACON
10-13
Table 10-9 The toolbar entries
10.5.3 Logging in and out and access levels
In order to keep your landing system safe and reliable, the opening of the RMM communica-
tion is secured with a
USERNAME and one to three PASSWORDS. The number of passwords cor-
responds to the
ACCESS LEVEL, which again give different permissions to the system as The
access levels shows.
Table 10-10 The access levels
After you have selected the MB station the Log On dialogue appears. Enter your
USERNAME,
use the tabulator on the keyboard or the mouse pointer to move to the
PASSWORD field and
View | Delays Open the delays view
View | TX settings Open the TX setting view
View | Users Open the user list view
Tools | Options Open the options dialogue
File | Snapshot to file Saves current monitor and maintenance data in tex-
tfile
Τ The system administrator will supply you with a user name and passwords
according to your access level.
Access level Permissions
1 • Readout of all the monitor values, warning and alarm limits.
• Readout of all the maintenance values and warning limits.
• Readout of all the delays.
• Readout of all the TX1 and TX2 configurations.
• Readout of users (only id's and last logout time)
2 • Level 1 +
• Turning on and off transmitters (same as using the front panel buttons)
• TX1 and TX2 : Using pre-programmed test settings.
3 • Level 2 +
• Settings of all the monitor warning and alarm limits.
• Settings of all the maintenance warning limits.
• Settings of all the delays.
• Settings of all the TX1 and TX2 configurations.
• Modulation tone settings to
NORMAL, CONTINUOUS or OFF on TX1/TX2.
• Start initialisation of modem.
Master • Level 3 +
• User administration
• Communications set-up
• Setting system date and time