Position Motor position is sent as actual value 1. See parameter 90.06
Motor position scaled.
6
50.08 FBA A actual 2 type Selects the type/source and scaling of actual value 2
transmitted to the fieldbus network through fieldbus adapter
A.
See parameter 50.07 FBA A actual 1 type.
Auto
50.09 FBA A SW
transparent source
Selects the source of the fieldbus status word when the
fieldbus adapter is set to a transparent communication profile
eg. by its configuration parameters (group 51 FBA A settings).
Not selected
Not selected No source selected. -
Other Source selection (see Terms and abbreviations on page 112). -
50.10 FBA A act1
transparent source
When parameter 50.07 FBA A actual 1 type is set to
Transparent or General, this parameter selects the source of
actual value 1 transmitted to the fieldbus network through
fieldbus adapter A.
Not selected
Not selected No source selected. -
Other Source selection (see Terms and abbreviations on page 112). -
50.11 FBA A act2
transparent source
When parameter 50.08 FBA A actual 2 type is set to
Transparent or General, this parameter selects the source of
actual value 2 transmitted to the fieldbus network through
fieldbus adapter A.
Not selected
Not selected No source selected. -
Other Source selection (see Terms and abbreviations on page 112). -
50.12 FBA A debug mode Enables the display of raw (unmodified) data received from
and sent to fieldbus adapter A in parameters 50.1350.18.
This functionality should only be used for debugging.
Disable
Disable Display of raw data from fieldbus adapter A disabled. 0
Fast Display of raw data from fieldbus adapter A enabled. 1
50.13 FBA A control word Displays the raw (unmodified) control word sent by the
master (PLC) to fieldbus adapter A if debugging is enabled by
parameter 50.12 FBA A debug mode.
This parameter is read-only.
-
00000000h …
FFFFFFFFh
Control word sent by master to fieldbus adapter A. -
50.14 FBA A reference 1 Displays raw (unmodified) reference REF1 sent by the master
(PLC) to fieldbus adapter A if debugging is enabled by
parameter 50.12 FBA A debug mode.
This parameter is read-only.
-
-2147483648 …
2147483647
Raw REF1 sent by master to fieldbus adapter A. -
50.15 FBA A reference 2 Displays raw (unmodified) reference REF2 sent by the master
(PLC) to fieldbus adapter A if debugging is enabled by
parameter 50.12 FBA A debug mode.
This parameter is read-only.
-
-2147483648 …
2147483647
Raw REF2 sent by master to fieldbus adapter A. -