Firmware Manual

Table Of Contents
556 Control chain diagrams
Torque limitation
Selection
Selection
30.30 Overvoltage control
Value
26.01 Torque reference to TC
Value
DC voltage
limiter
30.31 Undervoltage control
Value
Torque limiter
30.26 Power motoring limit
30.27 Power generating limit
30.19 Minimum torque 1
30.20 Maximum torque 1
26.02 Torque reference used
Current limiter
Load angle
limitation
Motor pull-out
limitation
30.17 Maximum current
Value
30.02 Torque limit status
To DTC core
Value
Selection
Value
Value
Value
Value
30.18 Minimum torque sel
Selection
Power to
torque limits
Value
Value
30.23 Minimum torque 2
30.24 Maximum torque 2
30.22 Maximum torque 2 source
30.21 Minimum torque 2 source
MAX
MIN
30.25 Maximum torque sel
Internal
torque lim
min
Internal torque lim max
30.02 Torque limit status
Bit Name
0 = Undervoltage
1 = Overvoltage
2 = Minimum torque
3 = Maximum torque
4 = Internal current
5 = Load angle
6 = Motor pullout
7 =
8 = Thermal
9 = Max current
10 = User current
11 = Thermal IGBT
12 = IGBT overtemperature
13 = IGBT overload
14 =
15 =