Hardware manual

Starting up fieldbus communication and programming the ABB PLC
98
speed_scaling
When a boolean "activate_scaling" is TRUE, action ‘speed_scaling’ scales the
speed reference and the actual value according to the ABB Drives profile. Action
converts an unsigned int actual value to a signed int actual value, by calculating the
two's complement
Tool/Step
Introduction to the actions