Product manual

Installation
Configuration of Welding Equipment
24 3HEA 801219-002 2005-05
4.2 Configuration of Welding Equipment
4.2.1 General
On delivery the equipment is configured according to the applicable configuration
data which is stored on the disk that comes with the delivery.
The data can be read and modified by way of the robot FlexPendant.
4.2.2 Installation disk
The following files on the installation disk contain configuration data for the weld-
ing equipment:
4.2.3 Reload configuration data
In case this configuration data must be reloaded, proceed in one of the following
ways:
As the disk is unique for the equipment supplied it should be stored in a safe place. The
program number indicated on the disk corresponds to the configuration in question, and
should be referred to in case of service matters regarding the function of the welding equip-
ment.
File Configuration data for:
RPB_FhpE.cfg
• welding power source RPB 320/420/520and
• wire feed unit A314E/316E/324E-L_PIB
Lrc_FhpE.cfg
• welding power source LRC 430 and
• wire feed unit A314E/316E/324E-L_PIB
MigRob_FhpE.cfg
• welding power source MigRob 500 and
• wire feed unit A314E/316E/324E-L_PIB
Alternative Description
Reboot the robot
The original configuration will be restored.
Loading using the
FlexPendant
In those cases where individual parameters need to be
changed compared to the original configuration.
Loading a new configuration
file
(EIO:CFG) Executed by way of the robot instruction:
System Parameters\File\Add or Replace
Parameters\ "file".cfg.
For more information, see “Configuration” on page 52.