Specifications
ABBRA INSTALLATION GUIDE Version.04 4/12/17 27 
APPENDIX C. Event Codes 
Contact ID Event Codes 
Code
Definition 
Code
Definition 
101  Emergency 
351  Telco fault 
110  Fire 
373  Fire detector trouble 
113  Flood alarm 
381  Loss of supervision RF
120  Panic 
383  Sensor tamper 
121  Duress 
384  RF low battery 
122  Silent 
393  Fire detector clean me 
123  Audible 
401  O/C by user 
131  Perimeter 
403  Auto arm 
132  Interior 
406  Cancel 
134  Entry/Exit 
408  Quick arm 
137  Tamper/CP 
426  Door open event 
139  Burglary verified 
441  Armed home 
151  Gas alarm 
454  Fail to close 
180  Gas trouble 
455  Fail to arm 
301  AC loss 
456  Partial arm 
302  Low system battery 
459  Recent close event 
311  Battery disconnect 
570  Bypass 
313  Engineer reset 
602  Periodic test report 
321  Bell 
607  Walk test mode 
344  RF receiver jam detect 
641  Senior watch trouble 
350  Communication trouble 
SIA Event Codes 
Code
Definition 
Code
Definition 
AR  AC Restore 
GJ  Gas trouble restore 
AT  AC Trouble 
HA  Holdup Alarm (duress) 
BA  Burglary Alarm 
LR  Phone Line Restore 
BB  Burglary Bypass 
LT  Phone Line Trouble 
BC  Burglary Cancel 
OP  Opening Report 
BR  Burglary Restore 
OT  Fail to Arm 
BT  Burglary Trouble / 
Jamming 
PA  Panic Alarm 
BV  Burglary Verified 
QA  Emergency Alarm 
BZ  Missing Supervision 
RN  Engineer Reset 
CF  Forced Closing 
RP  Automatic Test 
CI  Fail to Close 
RX  Manual Test 
CL  Closing Report 
RY  Exit from Manual Test 
CP  Auto Arm 
TA  Tamper Alarm 
CR  Recent Close 
TR  Tamper Restore 
EA  Door Open 
WA  Flood alarm 
FA  Fire Alarm 
WR  Flood alarm restore 
FT  Fire Detector Clean 
XR  Sensor Battery Restore 
FJ  Fire detector trouble 
XT  Sensor Battery Trouble 
FR  Fire Restore 
YR  System Battery Restore 
GA  Gas alarm 
YT  System Battery Trouble / 
Disconnection 
GR  Gas alarm restore 
YX  Service Required 
GT  Gas trouble 
4/2 Event Codes 
Note: Wireless siren reports to central station on zone 31 or 32. GSM reports to central station on zone 33. 
Alarms 
Zone # 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
1
st
 digit
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
2
nd
 digit
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Restorals 
Zone # 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
1
st
 digit
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
2
nd
 digit
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Supervisory trouble 
Zone # 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
1
st
 digit
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
7
7
7
7
7
7
7
7
7
7
2
nd
 digit
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
1
2
3
4
5
6
7
8
9
A
B
C
D
Low Battery 
Zone # 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
1
st
 digit
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
9
9
9
9
9
9
9
9
9
9
9
9
9
2
nd
 digit
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
1
2
3
4
5
6
7
8
9
A
B
C
D
Forced Arming – 8 users 
User No.   1  2  3  4  5  6  7  8 
1
st
 digit  A  A  A  A  A  A  A  A 
2
nd
 digit  1  2  3  4  5  6  7  8 
Zone Bypass 
Zone # 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
1
st
 digit
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
2
nd
 digit
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F