manually (interactive installation)
from the command line
using Active Directory
using Microsoft Systems Management Server (SMS)
The automated installation methods give you speed and flexibility when installing ABBYY FlexiCapture 10 on a local area net-
work, as you do not have to install the program manually on each individual workstation.
Manual (interactive) installation
To inst
all ABBYY FlexiCapture stations:
1. In the Autorun menu, select Distributed Installation.
2. Select Install Workstations to start the installation.
3. Select a setup language. The setup program will compare the locale of your system and the selected language. If the lan-
guages are incompatible, a warning message is displayed.
4. Next, the setup program checks the version of your operating system and the availability of the administrative permis-
sions. If the version of the operating system is not supported by the program or you do not have the administrative per-
missions, a warning message is displayed and the setup program is terminated.
5. If all the checks are passed successfully, the end-user license agreement will be displayed. Read the license agreement
carefully and if you agree with the terms of the agreement, select the corresponding option and click Next.
6. A dialog box will open prompting you to enter some information about yourself. Enter the required information and con-
tinue with the installation.
7. Next, select a destination folder. By default, the program is installed to: %systemdrive%\Program Files\ABBYY
FlexiCapture 10 Stations
8. Select the stations to install:
Scanning Station scans documents and sends them to the server for further processing
Processing Station automatically recognizes, imports, and exports documents; controlled by the Processing Server
Project Setup Station is used to set up projects on the server and local projects
Data Verification Station is used to verify uncertainly recognized characters
Verification Station is used to verify data, correct document assembly errors, handle exceptions
FlexiCapture Studio is a tool for creating FlexiLayouts
FormDesigner is a tool for creating forms
Just like the servers, the stations can be installed on the same or on different computers.
9. If a Processing Station is selected, a dialog box will appear where you must select the account under which the Process-
ing Station service will run. By default, the service runs under the user NETWORK SERVICE. If you plan to im-
port/export data on this station from/to a storage location with restricted user rights, or if this station is not in the domain,
you can specify the user that has the appropriate rights. In this case, the Processing Station service will run under this
user.
10. The program files will be copied onto your computer. Once the installation is finished, the setup program will display a
message saying that the application has been successfully installed.
11. If FlexiLayoutStudio, FormDesigner, Verification or Project Setup Station is installed, provide the address of the
Licensing Server in the next dialog box. The Licensing Server is installed via server installation. The address should not
contain slashes, for example: MainServer
Command line installation
In the def
ault configuration, all recognition languages are installed on the local computer and the interface language is selected
automatically based on the regional settings of the computer on which the program is installed. All stations are installed, and the
network name of the computer from which the setup program is run is used as the Licensing Server (in the case of standalone
installation, “localhost” is specified). The default user becomes the user of the Processing Station.
Run the setup.exe file located in the administrative installation folder using the command line options described below.
Advertise installation
For advertise installation, type
Setup.exe /j