Problem Comment Workaround
An error occurred during import:
Import failed.
Error: Unable to define fixed layout inside flexible.
This bug occurred when a
field was absent in an original
FlexiLayout, but the compiled
layout contained it.
Open the *.fsp project in
ABBYY FlexiLayout Studio 10
first to check that there are no
errors, and re-compile it.
Images do not match the converted fixed Document
Definition, although the same images matched the tem-
plate before conversion.
This happens due to signifi-
cant changes in technologies.
Open the converted Document
Definition in ABBYY FlexiCap-
ture 10, delete anchors, separa-
tors and static text, and re-create
them automatically or manually.
Some rules which can be converted (see the table) are not
converted.
In ABBYY FormReader 6.5, it
was possible to create several
rules which changed the value
of the same field. This isn’t
possible in FlexiCapture 10.
Check if you really need such a
complicated structure. Maybe,
you can solve the problem using
the standard ABBYY FlexiCap-
ture 10 features. If not, use the
“Script” rule.
In ABBYY FormReader 6.5 EE, multi-page documents
were processed. After conversion, several one-page
Document Definitions were created instead of a multi-
page Document Definition.
We cannot convert Custom
structure of documents be-
cause it isn’t supported in
ABBYY FlexiCapture 10. If
Custom structure was used in
FR65EE, one-page templates
will be imported. See
Documents and batches struc-
ture.
The documents structure is
described in the
FRE6BatchDefinition.sql file.
If this file was damaged or
deleted, only one-page tem-
plates will be exported.
Some complicated structures
cannot be created in ABBYY
FlexiCapture 10.
Check if the
FRE6BatchDefinition.sql file
wasn’t damaged or deleted.
There were annexes in the documents. The annexes are
not enabled in ABBYY FlexiCapture 10 Document Defi-
nitions.
In ABBYY FormReader 6.5, it
was possible to add annexes
using custom structure. We
cannot import custom struc-
ture of documents. See
Documents and batches struc-
ture.
Enable annex pages manually in
the Document Definition
Properties dialog box, Assem-
bly tab.
The rules are converted, new rules are created but the
order of rule execution differs from that in ABBYY
FormReader 6.5.
In ABBYY FlexiCapture 10
the order of rule execution
doesn’t depend on the user’s
specification, it depends on the
document structure.
Try to re-create rules in such a
way that they won’t depend on
the execution order.
If the order is very important,
try to create a “Script” rule
which covers all your rules.
FlexiLayout couldn’t be compiled. There are numerous changes
in ABBYY FlexiLayout Stu-
dio 10 compared to ABBYY
FlexiCapture Studio 1.5.
Open the *.fsp project in
ABBYY FlexiLayout Studio 10,
correct errors and re-compile it.
If there are errors, you will see
invalid elements with error de-
scriptions on the Errors tab.
Possible errors and workarounds
are described in the Errors in
converted FlexiLayouts section.
FlexiLayout has been compiled, but an error occurred
during matching of this FlexiLayout.
There are numerous changes
in ABBYY FlexiLayout Stu-
dio 10 compared to ABBYY
FlexiCapture Studio 1.5.
Open the *.fsp project in
ABBYY FlexiLayout Studio 10,
correct the code and re-compile
it.
Possible errors and workarounds
are described in the Errors in
converted FlexiLayouts section.
Errors which may occur while converting FlexiLayouts
Sometimes, the converted Flexible Description cannot be compiled, or there are errors during FlexiLayout matching.