Instructions

31
4.5. Warning by a closing signal
Approx. three seconds before the window closer closes after
your time set, a signal sounds.
If in your household children and persons with limited physical, senso-
ry, mental aptitudes or lack of experience and/or knowledge or pets
are present, the lower area of the window has to be equipped with
a sideward pinch protection (such as suitable profiles from the D-I-Y
store, accessory trade etc.). In this case please consult a specialist in
order to avoid possible dangers. Normally it is sufficient to protect
the lower third of the window. Has the window e.g. a height of 1 m,
the tilt window protection has to be approx. 30 cm.
4.6. Interruption of the closing operation
When you pull the release cord (A2) during the closing opera-
tion and hold it, the closing operation is interrupted. If you
release it, the closing operation will continue.
4.7. Battery change
Power supply of the window closers takes place via two LR6
(AA) - batteries. Rechargeable batteries must not be used.
We recommend the use of brand name alkaline batteries. As-
suming that a medium sized window two times a day
is closed, the batteries are to be changed after approx. two
years, that means after approx. 1500 closing operations.
WIN-CONTROL WS 20.1
32
WIN-CONTROL WS 20.1
Fig. 40: Removing the
batteries
Fig. 38 / 39: Removing the
bracket
The battery change takes place with window closed. When the
accessory rain sensor is installed, pull out first the male connect-
or (G1) of the rain sensor.
Remove now the bracket (A4). Hold the window closer with
one hand while removing the upper part of the housing of the
window closer in which are located the batteries by using the
other hand (fig. 38 / 39). Change the batteries as in fig. 40,
41, 42 shown.