Permanent short blinks Red
4.11.3 Buzzer melodies
The second interface from the tracker to the user is done via a buzzer. The volume can be managed using
buzzer_volume parameter.Different melodies have been defined:
Meaning Melody
Device is resetting/ going to bootloader Device reset
Device is starting Major rising scale
Device is going to OFF mode Major falling scale
Low battery detected Low battery
SOS mode is left SOS stop
Join failed 2 short beeps
Join success Join success melody
Proximity
Warning alert is triggered Proximity warning
Alarm alert state is triggered Proximity alert
A warning reminder is triggered proximity reminder 1 beep
An alert reminder is triggered proximity reminder 2 beeps
4.11.4 Reed switch interface
A Reed switch is an electrical switch operated by an applied magnetic field. It is used when no button is mounted
on the tracker. It can be configured with reed_switch_configuration parameter:
In button configuration, the Reed switch will act as described in section Button management A short
magnetic field input is recognized as a short press, and a long input, as a long press.
In specific behavior configuration, the reed switch will behave as follows:
A short input triggers on demand position.
A long input (more than 5s) triggers a device reset.