User Manual
the NVS data files). The NVS data file will be validated and stored to a location in the
complete RG system NVS. Subsequent boots will not go through this file transfer
process, but will load the NVS data directly from the complete RG system NVS.
Note: The WLS NVS data file will include the DIE_ID register value for verification
purposes.
WLS Manufacturing Test Process Summary:
1. Boot the WLS and test system.
2. Calibrate.
3. Save the NVS data file with the proper file name.
4. Deliver the NVS data file to the RG manufacturer in a mutually agreed upon fashion.
RG Manufacturing Process Summary:
1. Ensure the test PC has a TFTP server running with access to NVS data files from the
WLS manufacturer.
2. Boot the complete RG system.
The APDK automatically downloads the correct NVS data file to the complete RG
system NVS, and then loads the NVS data to the TNETW1350/A memory.
Note: Subsequent boots will not go through this file transfer process, but will load the
NVS data directly from the complete RG system NVS.
WCTXXXX/WMTXXXX