Manual
Page 7 of 7
HARDWARE:  Controls (Left):  STAGE 1 MOD (Manual)
    STAGE 2 MOD (Manual)
    STAGE 3 MOD (Manual)
    INPUT GAIN/ATTEN 
  Controls (Right):  STAGE 1 CV (External)
    STAGE 2 CV (External)
    STAGE 3 CV (External)
    OUTPUT GAIN/ATTEN
  Inputs (Signal):  1x DC, approx. +/-10V max. (3.5mm mono socket)
  Inputs (CV):  3x DC, approx. +/-10V max. (3.5mm mono socket)
  Outputs (Signal):  1x DC FULL-WAVE (3.5mm mono socket)
    1x DC HALF-WAVE (3.5mm mono socket)
  Power Requirements:  +/-12V via 16-pin, Doepfer-style IDC connector
  Current Draw:  80mA average
  Dimensions:  10HP (W); panel to IDC connector 35mm (D)
  Supplied Accessories:  1x 16-pin, Doepfer-style cable, 4x M3 screws
CALIBRATION:  AC-coupled inputs and outputs (i.e. most inputs and outputs that are used
  for AC and ‘audio’ signals) use a capacitor to remove constant DC content,
  leaving only the AC content of the waveform.
  The inputs and outputs of the ADE-10 are DC-coupled, which allows it to use
  both audio and CV signals (AC and DC) such as LFOs, gates, triggers, etc.
  as input and external CV input signals - but please note that any DC content
  present at the input will also be present at the output.
  Additionally, a non-calibrated ADE-10 can also add a small amount of DC
  content to the output waveform.
  Each ADE-10 is calibrated before shipping and once set, the output should
  remain at close to 0V DC with all front panel controls set to 0% and no
  inputs connected.
  For advice on calibrating the ADE-10 please contact Abstract Data.
PRECAUTIONS:  The ADE-10 uses the Doepfer standard for power connection and cable
  orientation. The RED stripe on the supplied power cable connects to the
  NEGATIVE (-12V) rail on the ADE-10 with the RED stripe facing DOWN.
  This is marked on the back of the ADE-10 PCB as “-12 RED”.
  (Please see ‘POWER CONNECTOR’ on page 3 of this guide)
  The ADE-10 has diode and polyfuse protection built in but an incorrectly
  connected cable may still cause damage to the module or the power supply.
  The rear panel of the ADE-10 has exposed parts and connections. Please
  ensure when handling the ADE-10 that the unit is held by the sides of the
  front panel or the sides of the PCB.
CREDITS:  Dr. Zoe Healey
  Rory Dow
  Matrix 
© 2011 Abstract Data Ltd. http://www.abstractdata.biz info@abstractdata.biz Version 1.0 October 2011
7: Technical