Installation Instructions

Screw Fasteners
Screw fasteners can be used if the screws do not restrict the normal expansion and contraction
movement of the vinyl I span wall paneling system on the wall. Screws must be centered in the
slot with approximately 1/16” (0.4mm) space between the screw head and the vinyl. Screws
must be able to penetrate not less 1” (24mm) into backing material keeping 1/16” (0.4mm)
space between the head and the vinyl.
Size #8, truss head or pan head
Corrosion-resistant, self-tapping sheet metal type
Staples
If staples are being used instead of nails or screws, they must:
Not be less than 16-gauge semi-flattened to an elliptical cross-section.
Penetrate not less than 1” (24mm) into backing material keeping 1/16” (0.4mm) space
between the crown and the vinyl
Cutting the vinyl I span wall panels
When cutting vinyl I span wall paneling system, follow these guidelines:
Safety goggles are always recommended for all cutting and nailing operations. As on any
construction job, use proper safety equipment and follow safe construction practices.
When using a circular saw, install the fine-tooth (plywood) blade backwards on the saw for a
smoother, cleaner cut, especially in cold weather. Cut slowly. Do not attempt to cut materials
other than vinyl with a reversed direction saw blade.
Caution! Use of a backwards blade on any other materials could be unsafe.
With tin snips, avoid closing the blades completely at the end of a stroke for a neater,
cleaner cut.
With a utility knife or scoring tool, score the vinyl face up with medium pressure and snap it in
half. It is not necessary to cut all the way through the vinyl.