Instructions

60
UK
changes its zone property during
internal activation to entry/exit and
starts the delay time if the zone triggers
and during active internal activation.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
062 Behaviour of exist mode internal active
(B)
To change the property of the exit mode for internal active
(B):
1. On the control unit, enter:
062
2. The LCD display shows: 062: B=LEISE
3. Via the keypad, select from the following items
and press:
0
Low Tone
The acoustic signal during the exit
delay time is emitted at half volume.
1
Instant
During internal activation, the alarm
centre is internally activated
immediately – i.e., without delay.
2
Silent
No acoustic signal is emitted during the
delay time. Following expiry of the delay
time, the alarm centre emits a brief
signal.
3
B=A
The initial mode for internal active B is
as for the initial mode of overall active A
In a partitioned system
0
B=Timed
Activation of partition B after exit time
(command 65). A connected key switch
at the control unit shortens the exit time
when activated
1
B=Terminated
Activated via key switch connected to
the control unit. The exit time is
unlimited.
2
B=Final Door
Activation of the partition by closing the
last door detector
3
B=Instant
Active without delay time
4
B=Silent
Use command 65 for the exit time. The
control unit emits a double beep when
the time has expired.
5
B=Lock Set
Key switch (see command 39)
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
063 Alarm behaviour for internal active (B)
To change the alarm property for internal active (B):
1. On the control unit, enter:
063
2. The LCD display shows: 063: B=Keypad
3. Via the keypad, select from the following items
and press:
0
B=Keypad
Only the control units are activated.
1
B=Internal
On alarm, the control units and the
internal alarm are activated.
2
B=Local
On alarm, the control units, the internal
alarm and the external siren are
activated.
3
B=Full
On alarm, the control units, the internal
signalling, the external sirens and the
telephone dialler are activated.
In a partitioned system
0
B=Keypad
Only the control units are activated.
1
B=Local
On alarm, the control units, the internal