70
UK
087 Control unit alarm
To change the properties of the connected control units:
1. On the control unit, enter:
087
2. The LCD display shows: 087:Dual Key OFF
3. Via the keypad, select from the following items
and press:
0
Dual Key OFF
If the function is deactivated, no alarm
can be emitted by the control unit.
1
Dual Key ON
If the function is activated, an alarm can
be emitted by the control unit. To trigger
an alarm, press the following keys:
1 & 3 for panic
4 & 6 for medical emergency
7 & 9 for fire alarm
For further information, see the
operating instructions of this product.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
089 Alarm confirmation
To change the properties:
1. On the control unit, enter:
089
2. The LCD display shows: 089:Confirm OFF
3. Via the keypad, select from the following items
and press:
0
Confirm OFF
The alarm centre is not programmed for
the signalling of confirmed alarms.
1
Confirm ON
The alarm centre is programmed for the
signalling of confirmed alarms.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
090 - 097 Test function see 16.6
098 Factory settings
To restore the factory settings:
1. You must be in program mode.
2. On the control unit, enter: 098
3. The LCD display shows: 098: Load Default
4. On the control unit, enter: 1
5. To restore the factory settings, press the following
key:
.
6. To abort, press: .
7. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
099 Exit program mode
To exit program mode:
1. On the control unit, enter:
099
2. The LCD display shows: 099: exit Eng ?
3. On the control unit, enter:
4. The control unit shows: SYSTEM TEST
5. If no fault exists and zones with the properties 24
hour, fire, panic or technical open are closed, you
exit the program menu.
6. If there is a fault, the alarm centre displays it.
Clear the fault and repeat steps 1–4.
101 Call mode TWG
Proceed as follows to change the property of call mode
telephone dialler (TWG):
1. You must be in program mode.
2. On the control unit, enter: 101