Installation Owner manual

74
UK
The alarm centre interprets a call as a
message from a remote PC. 10 to 90
seconds later, the remote PC calls
again once and the alarm centre
answers immediately on the first call.
(Set command 112 to a larger number
of calls than other end devices on the
line)
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
114 Call back mode
To change the settings:
1. On the control unit, enter:
114
2. The LCD display shows: 114:Callback OFF
3. Via the keypad, select from the following items
and press:
0
CallBack OFF
(the call to the remote PC must be
triggered manually – command 0 user
mode).
1
CallBack ON
The alarm centre answers after the set
number of calls. The alarm centre
hangs up and checks the ID and
software version of the remote PC.
After a short delay time, the alarm
centre calls back the PC (see command
118+119).
2
CallBack ANY
When deactivated, the alarm centre
answers after a set number of calls
(command 112+113) and accepts the
programming commands immediately.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
115 Telephone number 1
To change the settings:
1. On the control unit, enter:
115
2. The LCD display shows: 115:Tel No 1
3. Via the keypad, enter the telephone number.
Use key
A to enter a 4-second pause (shown by a
comma).
u
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer mode.
116 Telephone number 2
See command 115.
117 Client no. CS
With SIA formats the control unit can report alarms using
a six-digit account code. Account code 1234 becomes
001234. To change the settings:
1. On the control unit, enter:
117
2. The LCD display shows: 117:Account No
3. Use the keyboard to enter the numbers of the
client no. („account no“) for partition A.
Keys
C and D move the cursor to the right and
left.
u
4. Confirm your input. On the control unit, enter:
.
5. Repeat step 3 for the additional partitions.
6. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
Some European countries use letters in the account
number. The alarm centre accepts the letters B, C, D, E
and F. To enters letters, use the keyboard the same way
as when assigning the zone names.