Installation User guide

57
UK
3. On the control unit, enter:
4. The control unit shows: SYSTEM TEST
5. If no fault exists and zones with the properties 24
hour, fire, panic or technical open are closed, you
exit the program menu.
6. If there is a fault, the alarm centre displays it.
Clear the fault and repeat steps 1–4.
126 Change language
To change the language used for the control unit display:
1. On the control unit, enter:
126
2. The LCD display shows: 126:Lang=English
3. Via the keypad, select from the following items
and press:
00
ENGLISH
01
ITALIAN
02
ESPANOL
03
PORT
04
NEDERL
05
FRANCAI
06
GERMAN
07
NORW.
08
SWED.
09
DANSK
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
151 Additional outputs
By using the cable supplied or the optional relay PCB, you
have access to eight further transistor outputs. To change
the setting of output 1:
1. On the control unit, enter:
151
2. The LCD display shows: 151:Fire
3. Via the keypad, select from the following items
and press:
00
Not Used
01
Fire
02
PA
03
Burglar
04
Open / Closed
05
Alarm Abort
06
Technical Alarm
07
Alarm Confirmation
08
RF Low Battery
09
RF Supervision Loss
10
RF Jamming
11
AC Fail
12
Tamper Alarm
13
Open
14
Close
15
Zone Omitted
16
Medical
17
Keybox
18
Anti-Mask
19
Smoke Detector
30
Set 1
31
Set 2
32
Set 3
33
Set 4
34
Unset 1
35
Unset 2
36
Unset 3
37
Unset 4
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.