Technical data

A2 - III
3. New menu items in Installer Menu
3.1. FTS 96 E Detector, additional attribut for “Normal Alarm” zone type
Installer Menu Æ Detectors Æ Edit Zones Æ Attributes Æ Dis. Sabotage Yes /No
Factory setting: No
If “Yes” is selected, sabotage monitoring on the FTS 96 E wireless window protection system is switched
off when the alarm system is deactivated.
o “W” is shown in the “Attributes” line in the display.
3.2. System settings Jamming
Installer Menu Æ System Options Æ Jamming Æ Disabled
Fault
Fault + Sounders
Factory setting: Disabled
If “Fault” is selected, a warning is shown on the display when jamming is detected. If an output is
programmed for jamming, then this is switched. Communication measures set accordingly are also started.
If “Fault + Sounders” is selected, all signallers are also activated.
o Note: This setting does not conform to EN50131 standards!