Technical data

A2 - IV
3.3. Outputs - additional “Jamming” output type
Installer Menu Æ Outputs Æ Edit Outputs Æ Type Æ Jamming
The corresponding output switches when jamming is detected.
3.4. Communication , SPEECH DIALLER, additional “Jamming” event type
Installer Menu Æ Reporting Æ Speech Dialler Æ Report Triggers Æ Message x Æ Trigger x Æ Jamming
If “Jamming” is selected, the corresponding message is transmitted from the voice dialler when jamming is
detected.
4. Software changes
4.1. Reporting with ALARMS
The user of a key switch is transmitted with user ID 53.
4.2. Alarm signalling with “Technical Alarm” zone type
The wireless info module and wireless internal siren signal technical alarms using beep tones (in the same
way as the alarm centres).
4.3. New wireless accessory module
All new functions on the new wireless accessory module (2WAY sticker) can be used from this software
version onwards.