13.10 Selecting zone characteristics
Select the Attributes menu item.
Further properties can be allocated to the zone here.
Property Meaning
Chime
When the alarm centre is deactivated and this zone is
triggered, the centre emits an acoustic signal.
Soak Test
If a detector tends to trigger false alarms, activate the
detector test (soak test). This setting is automatically
reset after 14 days. During this time, the detector
triggers no alarms on the alarm centre. All triggering
behaviour is noted in the memory (logbook).
Activity Mon.
The detector function is inverted. This is only to be
used in connection with the Social Care function. An
alarm is triggered on the alarm centre if the detector
reports no alarms within a specific period.
Part Set
This zone is monitored if the partition of this zone or all
partitions are internally activated.
Force Set
If a zone is assigned this property, then this zone is hid
automatically if it was open during activation.
13.11 Examples of zone properties
Part Set:
Detectors with the Part Set attribute secure your property from the outside.
You can move freely around the property.
This means:
The alarm centre only reacts to
detectors with the Part Set
property.
Force Set:
An interior door is secured with an opening detector. The detector is assigned the
Force Set property. The system can then also be activated when this door is open.
This detector is then no longer used for monitoring.
The Force Set function must be activated additionally in the System
Settings / Force Set menu.
The Soak Test function should only be set when the detector has a
tendency of triggering false alarms. This function works automatically.
To test the detector range, use the walk test function. Do not activate
the detector test, as this function ensures that a message is stored in
the memory and no alarms are triggered when the wireless alarm
system is activated. The wireless alarm system sets the zone back to
normal after 14 days.