Technical data
53
Type Meaning
Not Used This output is not in use and is never activated.
(Exception: complete power loss).
Local This output is activated on local alarms for the defined
siren duration.
E/E Follow This output is activated for the duration of the delay time
(entry/exit delay active).
Armed Lamp This output is activated as long as the alarm centre is
internally or externally activated.
24 Hour This output is activated if a 24-hour zone triggers an
alarm.
Strobe This output is activated for a local alarm and remains
active until the wireless alarm centre is deactivated.
Strobe Set This output is activated for approx. 10 seconds following
successful activation of the wireless alarm centre and is
used for acknowledging activation. The function must
also be activated in the partition menu. This output is
also activated for a local alarm and remains active until the
wireless alarm centre is deactivated.
Pulse Set This output is activated for approx. 1 second following
successful activation of the wireless alarm centre.
Pulse Unset This output is activated for approx. 1 second following
successful deactivation of the wireless alarm centre as
well as for a panic or fire alarm.
Setting Complete This output is activated for approx. 10 seconds following
successful activation of the wireless alarm centre.
Siren P1 - P4 This output is activated on local alarms in the selected
partition for the defined siren duration.
Strobe Set P1 - P4 This output is activated for a local alarm in the selected
partition and remains active until the wireless alarm centre
is deactivated. The output is also activated for 10 seconds
after successful activation of the partition.
Technical This output is activated if a technical zone triggers an
alarm.
Medical This output is activated if a medical emergency call is
activated.
Panic This output is activated if a panic alarm is activated.
Fire This output is activated if a fire alarm is activated.
Zone Follow This output follows the state of a zone. An overview of
zones is displayed when this type is selected. Select a
corresponding zone.
User Defined This zone can be remote-controlled by various
components such as remote control units or the code
keypad. The output can also be assigned times at which it
is to be activated and deactivated. If this output type is
selected, the times at which the output is to be activated or
deactivated can be entered at the end (see the note
below).
FullSet RDY P1 - P4 This output is activated when the partition is ready to be
activated.
Part Set P1 - P4 This output is activated if a partition is internally activated.
Full Set P1 - P4 This output is activated if the partition is activated.
Select the function User Defined, for example.
End data entry by pressing Back.