Technical data
55
14.7 WAM outputs
The WAM wireless outputs can be edited after training the WAM as a wireless
transmitter or receiver (function 3).
Select output 31 using the arrow keys (WAM 1).
Edit the menu point under output 31
.
Select the Name
menu item.
Assign a new name and finish data entry by pressing OK
.
Select the Type
menu item.
An overview of output types can be found in the following table.
Type Meaning
Not Used This output is not in use and is never activated. (Exception:
complete power loss).
Local This output is activated on local alarms for the defined siren
duration.
E/E Follow This output is activated for the duration of the delay time
(entry/exit delay active).
Armed Lamp This output is activated as long as the alarm centre is
internally or externally activated.
24 Hour This output is activated if a 24-hour zone triggers an alarm.
Strobe This output is activated for a local alarm and remains active
until the wireless alarm centre is deactivated.
Strobe Set This output is activated for approx. 10 seconds following
successful activation of the wireless alarm centre and is used
for acknowledging activation. The function must also be
activated in the partition menu. This output is also activated
for a local alarm and remains active until the wireless alarm
centre is deactivated.
Pulse Set This output is activated for approx. 1 second following
successful activation of the wireless alarm centre.
Pulse Unset This output is activated for approx. 1 second following
successful deactivation of the wireless alarm centre as well as
for a panic or fire alarm.
Setting Complete This output is activated for approx. 10 seconds following
Please note that the disconnected WAM outputs have a maximum load
of 500 mA at 24 V. This is an opto-isolator with a forward resistance of
2 Ω.
WAM 1 output 1
Secvest output 31
In the installer menu:
Æ Æ
Select the Edit Output menu item.