Technical data

66
16. Partitions
Select the corresponding function.
For an overview of functions and their attributes, see the table below.
Function Meaning
Name Select this point to rename a partition. Enter the name in the
same way as for zones or output names.
Type Select this point to define the output mode of the partition.
Properties of each output mode can be found in the next
section.
Exit Delay Exit delay times 10, 20, 30, 45, 60 or 120 sec.
Entry Delay Entry delay time 10, 20, 30, 45, 60 or 120 sec.
Response Response in the event of an alarm in this partition.
Part Set Behaviour of this partition at internal activation (exit delay).
P.Set FE As Behaviour of entry/exit zone at internal activation. The
options are as follows:
FE as FE – The entry/exit zone retains the entry/exit
attribute even for internal activation.
FE as NA – The entry/exit zone changes its attribute at
internal activation to “Instant Set”.
P.Set ER As Behaviour of the “Entry Route” zone at internal activation
(ER remains ER or ER becomes FE).
Strobe Follow Set Behaviour of activation acknowledgement. The options are
as follows:
OFF – No visual acknowledgement on external siren after
successful activation (not internal).
ON – Visual acknowledgement on external siren after
successful activation (not internal).
Strobe Follow Unset Behaviour of deactivation acknowledgement. Programming
is made in the same way as activation acknowledgement.
16.1 Partition types
Select the corresponding exit mode.
For an overview of exit modes and their attributes, see the table below.
Function Meaning
Timed Set The partition is activated following expiry of the defined exit
time.
User Defined The partition is activated when a zone is closed with the
entry/exit property.
Instant Set The partition is activated immediately. This exit mode is
recommended for activation over remote control or wireless
cylinders.
Silent Set Same as the “Timed Set” exit mode, except that no exit signal
can be heard during the delay time.
As Prtn 1
This option is available for partitions 2, 3 and 4. When this
option is selected, the system uses the same type as for
partition 1.
Do not attempt to use a PIR zone as the input or output for a partition.
PIR wireless detectors have an inactive period after each activation to
save battery power. When a partition is activated (or activated
internally), the PIR detector may still be blocked. During this time, no
signal for completion of the activation process can be sent.
In the installer menu:
Æ
Select Partitions.