Technical data

68
Behaviour of activation acknowledgement. The options are as follows:
OFF – No visual acknowledgement on external siren after successful activation (not
internal).
ON – Visual acknowledgement on external siren after successful activation (not
internal).
Behaviour of deactivation acknowledgement.
Programming is made in the same way as activation acknowledgement.
17. System options
Select System Options.
Select the corresponding function. For a list of functions and their attributes, see the
table below.
Function Meaning
User Access In this menu, the options available to the user in the user
menu are defined.
Remote Access This menu controls the access of remote control functions.
Language Select the language for voice output and the graphic
displays. You can choose between two languages.
Restore Defaults Used for restoring the factory settings and setting the
country parameters (important for telephone
communication).
Installer Code Used for entering a new user code.
Deactivate Delay Used for deactivating the alarm centre / partition using the
remote control within the entry delay time.
When this function is activated, the alarm centre can only
be deactivated using the remote control within the entry
delay time. When this function is deactivated, the wireless
alarm centre can be deactivated using the remote control at
any time.
PA Response Used for setting the behaviour in the event of a panic alarm.
Auto Rearm Used for setting the alarm centre response following an
alarm.
Siren Delay Used for setting the length of the siren delay.
Siren Time Used for setting the siren duration.
Delay On Entry Alarm Used for setting the delay time for an entry alarm.
Supervision Used for setting the response of the alarm centre in the
event of supervision failure.
Jamming Used for setting the response of the alarm centre in the
event of wireless jamming.
Batt Load Test Used for activating the battery test function.
Siren in PSet Used for controlling the siren properties with an internally
activated system.
Force Set Used for activating and deactivating the Force Set function
or activating it with a confirmation.
RF Siren Options Used for setting the response of the wireless siren.
17.1 Configuring the system options
Select the corresponding options for the user from the table. To activate a function for
the User, press Change.
The option must be set to “Y” in order for it to be used.
Function Meaning
Record Voice Memo Enables the user to record a voice message.
Reset After Alarm Enables the user to reset the wireless alarm centre
following an alarm using the user code. When “N” is
selected, the user can only set the alarm to silent. The
administrator must reset the system by entering the user
code.
Dual key function Activates the alarm buttons on the keypad for the user.
Zone Tamper Reset Enables the user to reset the wireless alarm centre with
the user code following a tamper alarm. When “N” is
selected, the user can only set the alarm to silent. The
administrator must reset the system by entering the user
code.
Omit All Enables the user to lock all open zones simultaneously
with a single button.
Social Care Key Activates the “Social Care” key on the keypad for the
user.
Quick set Enables the activation of the alarm centre without a user
code.