Technical data

80
20.10 SIA Report Mode
Select this, then select the Level of the transmission. The following table details which
events should be transmitted for the SIA 1 report.
Trigger Basic SIA
code
without
zone no. or
user
Sum SIA
code without
zone no. or
user
Middle SIA
code with
zone no.
and user
Complete SI
A
code with
zone no.
and user
Medical control panel MA MA MA MA
Fire FA FA FA FA
Fire control panel FA FA FA FA
Fire control panel OK - FR FR FR
Fire OK - FR FR FR
Panic PA PA PA PA
Panic control panel PA PA PA PA
Panic control panel OK - PR PR PR
Panic OK - PR PR PR
Burglary BA BA BA BA
Burglary OK - - BR BR
Cover tamper contact - TA TA TA
Cover tamper contact OK - - TR TR
Tamper ext. siren - - TA TA
Tamper ext. siren OK - - TR TR
Tamper sensor TA TA TA TA
Tamper sensor OK - - TR TR
Tamper system - TA TA TA
Tamper system OK - - TR TR
Key box open - - BA BA
Key box closed - - BR BR
Technical alarm - UA UA UA
Technical alarm OK - UR UR UR
Power failure - - - AT
Power failure OK - - - AR
Reset - OR OR OR
Battery fault - - - YT
Battery fault OK - - - YR
Battery missing - - - YM
Battery missing OK - - - YR
ISDN/GSM fault - - - LT
ISDN/GSM fault OK - - - LR
PSTN fault - - - LT
PSTN fault OK - - - LR
Jamming - - XQ XQ
Supervision fault - - BZ BZ
Supervision fault OK - - - -
RF battery fault - - XT XT
Set - CL CL CL
Internal active - CL CL CL
Unset - OP OP OP
Key switch set CS CS CS CS
Key switch unset OS OS OS OS
Download successful - - RS RS
Tamper user code - JA JA JA
Omit zone BB BB BB BB
Man. trigger test report RX RX RX RX
Period. test report RP RP RP RP
Time / day changed - - - JT
Prog. mode start - LB LB LB
Prog. mode end - LS LS LS
User code changed - - - JV
User code deleted - - JX
Default password setting
loaded
- - RH RH
End time limit EA EA EA EA
20.11 SIA Report Restorals
Select whether the restoration of a function (closing of an alarm zone, error clearance)
should be transmitted to the command centre. If this function is disabled, only faults or
alarms are transmitted to the command centre but not the restoration (OK message) of
this function.
The following connection is recommended in Germany and Austria:
Under “Report Type”, select SIA 1
Under SIA Report, select Basic
The codes are now transmitted according to the table without zone
numbers and users.
Under SIA Report, select Sum
The codes are now transmitted again according to the table without zone
numbers and users.
Under SIA Report, select Middle
The codes are now transmitted again according to the table with zone
numbers and users added.