Technical data
81
20.12 Contact ID Reports
Select whether the restoration of a function (closing of an alarm zone, error clearance)
should be transmitted to the command centre. If only the basic function is enabled,
only faults or alarms are transmitted to the command centre but not the reset of this
function.
All transmitted messages are listed in the table. If “Basic + Restore” is selected, then
all messages plus their reset command are transmitted.
Trigge
r
CID Basic code with zone
no. and user
CID Basic + Restore
code with zone no. and
user
Medical control panel 100 100
Fire 110 110
Fire control panel 110 110
Fire control panel OK - 110
Fire OK - 110
Panic 120 120
Panic control panel 120 120
Panic control panel OK - 120
Panic OK - 120
Burglary 130 130
Burglary OK - 130
Cover tamper contact 137 137
Cover tamper contact OK - 137
Tamper ext. siren 137 137
Tamper ext. siren OK 137 137
Tamper sensor 137 137
Tamper sensor OK 137 137
Tamper system 137 137
Tamper system OK 137 137
Key box open 150 150
Key box closed 150 150
Technical alarm - 150
Technical alarm OK 150 150
Power failure 301 301
Power failure OK - 301
Reset 305 305
Battery fault 311 311
Battery fault OK - 311
Battery missing 311 311
Battery missing OK - 311
ISDN/GSM fault 351 351
ISDN/GSM fault OK - -
PSTN fault 351 351
PSTN fault OK - -
Jamming 380 380
Supervision fault 381 381
Supervision fault OK - -
RF battery fault 384 384
Set 401 401
Internal active 401 401
Unset 401 401
Key switch set 409 409
Key switch unset 409 409
Download successful 412 412
Tamper user code 461 461
Omit zone 573 573
Man. trigger test report 601 601
Period. test report 602 602
Time / day changed 625 625
Prog. mode start 627 627
Prog. mode end 628 628
User code changed - -
User code deleted - -
Default password setting
loaded
- -
End time limit - -
When the “CONTACT ID Basic” report type is selected, the codes are transferred
according to the table including the zone numbers and users.
20.13 Force Test Call Now
Use this option to start a test call immediately on the wireless alarm centre.
Select the Force Test Call Now menu item.
When Force Test Call Now is confirmed with Select, the wireless alarm centre opens
communications with the emergency command centre immediately.
20.14 Dynamic Test Call
Select whether the wireless alarm centre should make a test call every 24 hours.