20.36 Call Mode
This option is used to activate or deactivate SMS communications.
20.37 Primary Telecoms
Select which primary transmission path should be used. This transmission path is used
as long as transmission is possible using it.
20.38 Messages
Select the corresponding function. For a list of functions and their attributes, see the
table below.
Function Meaning
Home Message
The home message can be 12 characters long. Use the text
to identify the wireless alarm centre. The alarm centre sends
the home message text to each telephone number
programmed for SMS messages. The alarm centre sends the
home message text at the beginning of each SMS message.
Trigger message 1-
4
Each numbered message can be 30 characters long. Enter a
message that relates to the type of alarm trigger selected.
20.39 Phone Book
Enter the phone numbers to be dialled.
The alarm centre sends as follows:
Message 1 to phone number 1
Message 2 to phone number 2
Message 3 to phone number 3
Message 4 to phone number 4
Press the star key to enter a dial pause. The dial pause is displayed as a comma.
Each dial pause interrupts the dial procedure for 3 seconds. The display can then be
used to enter a name for this number. The alarm centre shows these names in the
phone book so that you can see which destination was used for the message.
20.40 SMS Triggers
Select a trigger. For a list of triggers and their attributes, see the table below. A set of
alarm triggers can be connected to each message. “Y” can be entered next to
more than one trigger in the list.
Trigge
r
Meaning
Tamper Transmits an SMS in the event of a tamper alarm.
Alarms Transmits an SMS in the event of an alarm (fire, panic
etc.).
Sets/Unsets Transmits an SMS when the alarm centre is
activated/deactivated.
System Transmits an SMS in the event of a system trigger.
20.41 PSTN S MS
If SMS messages should be sent over the PSTN line but no GSM module is attached,
then additional data must be programmed in this menu. It is possible to send SMS
messages over many analogue telephone connections. To do this, the connection
must be authorised and all telecommunications devices between the APL or first TAE
sockets and the alarm system must support the CLIP function.