System Control:
Quick-Key Parameter Default Range
11
22
1414
Audible Jamming NO
YES/NO
Refers to Jamming Time, which is described on page 7-32.
Y
ES: If the defined jamming time is reached, the ABUS wireless alarm system
activates the sounders. (See Jamming Trouble, page 7-32.)
NO: Jamming does not trigger an audible alarm.
11
22
1515
Technician Tamper NO
YES/NO
Y
ES: The program PIN is required for resetting a tamper alarm. First, the OK
message must be received from the detector or the tamper zone must be
closed.
NO: A tamper alarm is reset with the OK message of the detector or when the
tamper zone is closed.
11
22
1616
Technician Reset NO
YES/NO
Y
ES: Following an alarm, the program PIN must be entered to be able to reactivate the
system.
NOTE:
Before the Ready LED can light up, all zones in this area must be closed.
NO: The alarm system can be activated immediately following an alarm if all zones are
closed and the Ready LED is on.
11
22
1818
Summer/Winter Clock
Y
ES
YES/NO
Y
ES: The ABUS wireless alarm system automatically puts its clock forward
one hour forward in spring (last Sunday in March) and one hour back in
autumn (last Sunday in October).
NO: No automatic time adjustment
11
22
1919
Forced Keyswitch Arming
Y
ES
YES/NO
Y
ES: If the system or an area is activated by a key-switch, all open zones are
automatically omitted from monitoring. The remaining zones are monitored. The
system/area is monitored in every case.
NO: The system/area can be activated only if all zones are closed and the system/area
is ready for activation.
11
22
2020
Pager NO
YES/NO
Enables alphanumeric output of system events on a pager. The number of the pager
must be programmed like a Follow-Me number.
Y
ES: For the activated/deactivated event and the alarm event, the system sends
information to the pager.
NO: The system transmits no events to pagers.