Specifications

7-45
22
22
44
ZZZZ
+
1818
Exit Termination
A
zone with the Exit Termination zone type behaves like a zone with the Exit(OP)/Entry
zone type. However, the difference is that an exit delay time is ended immediately if this
zone is opened or closed during the exit delay time.
When you enter the protected area, the entry delay time of Group 1 starts as usual.
22
22
44
ZZZZ
+
1919
Latch Keyswitch
A
zone with the Latch Keyswitch zone type is used for activating/deactivating one or
more areas. The area remains active as long as the zone is open, and is deactivated
as soon as the zone is closed.
22
22
44
ZZZZ
+
2020
Entry Follower + Stay (Internal)
If armed, this zone works like a zone type Entry Follower. If stay armed this zone type
works like an exit/entry zone of Group 1.
22
22
44
ZZZZ
+
2121
Keyswitch Delay
A
zone with the Keyswitch Delay zone type is used for activating/deactivating
one or more areas. This zone type is comparable to zone type Key switch,
except that the area is first activated following expiry of the entry/exit delay
time of Group 1.
22
22
44
ZZZZ
+
2222
Latch KSW Delay
A zone with the Latch KSW Delay zone type is used for
activating/deactivating one or more areas. The area remains active as long as
the zone is open, and is deactivated as soon as the zone is closed. This zone
type is comparable to zone type Blockschloss, except that the area is first
activated following expiry of the entry/exit delay time of Group 1.
22
22
44
ZZZZ
+
1010
I+Instant
(Interior+Instant)
A
rmed
The I+Instant zone type is similar to zone type Instant. However, this zone type is not
monitored for an internally activated system.
22
22
44
ZZZZ
+
1111
UO Trigger
A
rmed
The UO Trigger zone type controls a switch output whether the system is active or inactive.
For example: for temperature sensors that control a ventilator.
22
22
44
ZZZZ
+
1212
Day Zone
A
rmed
A
zone with the Day Zone zone type immediately triggers an alarm in an internally or
externally activated system. If the system is inactive, a fault is displayed on the alarm
system display. The fault message can now control a switch output or be viewed by the
user in the user menu under Troubles. This zone type is mostly used to protect emergency
exits.
22
22
44
ZZZZ
+
1313
24 Hours
Default for zone 3
A
ll
A
zone with the 24 Hours zone type triggers an alarm immediately, irrespective of the
state of the alarm system. This zone type is mostly used for passive glass breakage
sensors.
22
22
44
ZZZZ
+
1414
Fire
Default for zone 3
A
ll
A
zone with the Fire zone type triggers a fire alarm immediately, irrespective of the state of
the alarm system. This zone type is used for smoke detectors.
NOTE:
Zone 33 cannot be programmed as a fire zone.
22
22
44
ZZZZ
+
1515
Panic
A
ll
A
zone with the Panic zone type triggers a panic alarm immediately, irrespective of
the state of the alarm system. This zone type is not intended for panic messages
triggered by remote control. See the key-fob menu.
22
22
44
ZZZZ
+
1616
Special
A
ll
A
zone with the Special zone type triggers a medical emergency alarm (not a panic
alarm) immediately, irrespective of the state of the alarm system.
22
22
44
ZZZZ
+
1717
Pulse Keyswitch
A
zone with the Pulse Keyswitch zone type can be used to activate/deactivate an
area. The state change must be in the form: closed – open (pulse) – closed.