Soak Test
Some wireless detectors tend to trigger alarms more than others. The Soak Test
was developed to test these detectors over a longer period without triggering an
alarm.
Up to 8 zones can be programmed for the Soak Test. A zone programmed for the
Soak Test is omitted for 14 days while the alarm system is active. If no alarm is
triggered by this detector for 14 days, the tested zone is automatically reintegrated
in the system.
If one of the zones programmed for the Soak Test sends an alarm within these 14
days, the alarm system does not trigger an alarm but registers a fault message
instead. You can see the fault message in the user menu.
The 14-day period for the joint test of alarm lines is then set to zero and restarted.
To add a zone to the Soak Test:
Press
22
. You see the following on the display:
To add a zone to the Soak Test, press
. You see the following on the display:
Enter the zone number (e.g., 01 for Zone 1) and press
. The menu jumps to the
next assignment number.
To add a second zone to the Soak Test, press and repeat the above procedure
- OR -
Press
to return to the previous menu.
If you enter zone number 00, no zone is assigned to the Soak Test.
7.3.4
22
44
Editing
Under Editing, you can copy and delete programmed zones.
To access the Editing menu:
1. Select the Zones menu as described on page 7-37.
2. In the Zones menu, press
44
to get to the Editing menu option. You see the following on the display: