Smartvest User manual You can find important information and FAQs about this and other products online at: www.abus.com Version 1.2 English translation of the original German user manual. Retain for future reference.
English Introduction Dear Customer, Thank you for purchasing this product. This device complies with the requirements of the applicable EU directives. The declaration of conformity can be obtained from: ABUS Security-Center GmbH & Co. KG Linker Kreuthweg 5 86444 Affing GERMANY To ensure this condition is maintained and that safe operation is guaranteed, it is your obligation to observe this user manual.
English Explanation of symbols The triangular high voltage symbol is used to warn of the risk of injury or health hazards (e.g. caused by electric shock). The triangular warning symbol indicates important notes in this user manual which must be observed. This symbol indicates special tips and notes on the operation of the device. Lists 1. … 2.
English Power supply Only operate this device using a power source which supplies the grid voltage specified on the type plate. If you are unsure which power supply is available, contact your utility company. Disconnect the device from the power supply before carrying out maintenance or installation work. To fully disconnect the device completely from the mains, the mains plug must be withdrawn from the mains socket.
English Installation location/operating environment Place or mount the device on a steady, level surface and do not place any heavy objects on the device. Make sure that there is adequate ventilation (do not place the Smartvest on a shelf, thick carpet, bed or wherever the ventilation slits may be covered. Always leave a gap of at least 10 cm on all sides). The Smartvest is not designed for operation in rooms prone to high temperatures or humidity (e.g. bathrooms) or excessive dust accumulation.
English Unpacking the device Handle the device with extreme care when unpacking it. Packaging and packaging aids can be reused and, as far as possible, should be sent for recycling. We recommend the following: Paper, cardboard and corrugated cardboard as well as plastic packaging items should be placed in the appropriate containers provided. If no such facility exists in the area, these materials should be put into the general household waste.
English FUMK35000 magnetic contact .............................................................................................. 12 FUBW35000 PIR Motion Detector......................................................................................... 13 FURM35000 smoke alarm/heat detector .............................................................................. 13 FUSG35000 siren ..................................................................................................................
English 1. Device description This chapter contains descriptions of the Smartvest and all associated components. FUAA35000 Smartvest Front Power LED Status LED On System is supplied with power Off No power supply Off System is "disarmed" Yellow On The system is "disarmed" and there is a fault (e.g.
English Under side To reset passwords to the default settings (123456) and network settings to DHCP: While the system is in operation, press and hold the reset button for >10 seconds using a paper clip. The power LED will go out and a continuous tone will sound. The system then restarts. Reset button Resetting the system to the default settings means that all settings are reset and component pairings are deleted.
English Rear 6 x AA (1.5 V) batteries for backup power supply (approx. 5h battery life) Changing the battery Push the clips to open the battery compartment cover. Remove the dead 6 AA (1.5 V) batteries from the compartment and replace with the new 6 AA (1.5 V) batteries. Make sure they are facing in the direction shown on the compartment floor, then close the battery compartment by replacing the cover.
English FUHA35000 power switch Schuko socket Schuko socket type F (CEE 7/4). Can be used in the following countries: Germany, Austria, Sweden, Netherlands Blue Status LED Orange Off Power switch is activated; power is being transmitted. On Power switch is ready and activated; power is not being transmitted to the consumer. Flashing Power switch is starting up Flashing Repeater mode started On Power switch is ready and activated; power is not being transmitted to the consumer.
English FUMK35000 magnetic contact Transmitter component Contains a wireless component Mounted on window frame Signal LED Blue Flashing Magnetic contact is closed Magnetic contact is opened 1x 3V button battery (CR2032) for power supply (up to one year battery life). The Smartvest App warns you when the battery is low. Follow the instructions in the app. Battery operation Magnet component Changing the battery Slide the battery compartment cover out in a downwards direction.
English FUBW35000 PIR Motion Detector Catch Catch for removing the rear panel Pair button Button for manual pairing with the Smartvest Activate test mode: press for 5 s Deactivate test mode: press for 5 s Tampering contact Tampering contact for alarming in the event of unwanted removal 3 x AA (1.5 V) batteries for power supply (up to two years battery life) The Smartvest App warns you when the battery is low. Follow the instructions in the app.
English FUSG35000 siren LED chamber LED flashes (according to setting) in the event of an alarm and to acknowledge changes to the siren settings. Loudspeaker Siren loudspeaker with a maximum volume of 80 db or 100 db. Pair button Button for manual pairing with the Smartvest Tampering contact Tampering contact for alarming in the event of unwanted removal 4 x C (1.
English FUBE35000 Remote Key Signal LED Blue Arm button Button for arming the Smartvest Press and hold for 5 seconds to switch internally armed Disarm button Button for disarming the Smartvest Camera button Button to start recording for connected cameras Panic button Button for triggering the panic alarm (press for 3 seconds) Flashing Acknowledges when button is pressed 1x 3V button battery (CR2032) for power supply (up to two years battery life) The Smartvest App
English 2. Start-up Before installing your Smartvest and detector, follow the steps below to start up your Smartvest and pair components with the Smartvest. Installing the Smartvest App For the Smartvest, there is an app called "Smartvest" available for download from the Google Play Store and the iOS App Store. This app can be used on smartphones and tablets, referred to as "end devices" from this point on. For installation, go to the Google Play Store or the iOS App Store and search for "Smartvest".
English Open the Smartvest App and carry out the following steps: Start setup Tap the plus sign to add a Smartvest. The app then automatically searches for devices on your network. Select Select your Smartvest from the list. If you want to link the Smartvest from another network or the Smartvest is not found, enter the DID manually. All further entries must then also be made manually. Device security code The standard security code "123456" is already stored.
English Name assignment, room and location information Assign a name to the Smartvest. The name "Smartvest" will be stored initially. Open the room list and select a room where the Smartvest is mounted. Tap the arrow to return to the previous window. To display weather information, tap the town row and search for your location using the place name or postcode and select your location from the results returned. Note The location data is used solely to ascertain weather information.
English Pairing components Open the Smartvest App and connect to the Smartvest. Note The settings for your components can be found in chapter 5.1, Components. Carry out the following steps: Open Smartvest settings To access the Smartvest settings, tap the settings symbol in the bottom left-hand corner of the operation view. Enter the settings password (standard: "123456") to access all settings options.
English Pair components Enter a name for the component. Note The name must have a maximum of 15 characters. Additional characters will be automatically deleted after saving. Open the room list and select the room where the component is installed. Tap the arrow to return to the settings. Now tap "Next". Follow the instructions in the app. Attention If automatic pairing has not worked as per the instructions provided, there is a procedure for manually pairing each component.
English Removing components Open the component list and... For Android: … slide the components to the right-hand edge of the screen and confirm removal For iOS: … slide the components to the left-hand edge of the screen and press "Delete" General settings Open the Smartvest App and tap the settings symbol top right-hand corner to access the general settings. in the Available systems Add a new Smartvest to the app or select your Smartvest to access the Smartvest's general settings.
English App security Tap "Change app PIN" to enter your own app PIN. During the initial setup, the standard app PIN "123456" is stored. Attention If the app PIN is enabled, you will be asked to enter this each time you start the app on your end device. If you have forgotten your app PIN, you must delete the app and reinstall it. Standard app PIN: "123456" Disable "Automatic log in" for the app PIN to ensure the app PIN is requested each time the app is started.
English 3. Installation This chapter describes how to install the Smartvest and the associated components. Please refer to chapters 4 and 5 when operating and adjusting the settings for the Smartvest via the Smartvest App. Warning When using adhesive pads, ensure that the surface below is clean, abrasion-resistant and dry. On account of their properties, wallpaper and polystyrene or surfaces coated with silicone or Teflon are not suitable for the installation of the smoke alarm device.
English Wall installation Stick the Smartvest drilling template to the desired installation location. Use a spirit level to ensure the drilling template is straight. Drill holes in the specified positions and insert the screw anchors provided. Screw the screws provided into the screw anchors so that the heads protrude by around 6 mm, then mount the Smartvest. FUHA35000 power switch The power switch is only suitable for indoor use.
English Installation with adhesive pads (recommended) 1. Stick both the small adhesive pads on to the magnetic contact's large transmitter components and the longer adhesive pad on to the smaller magnet component. 2. Stick the large transmitter component to the window frame in the desired position in relation to the window and stick the smaller magnet component to the window itself. Installation with screws 1. Open the magnetic contact's smaller magnet component with a thin slotted screwdriver. 2.
English FUBW35000 PIR Motion Detector The motion detector is only suitable for indoor use. For further information, please refer to the safety instructions relating to installation location and operating environment. General installation instructions Install the motion detector 2–2.5 m above the ground for a range of 12 m. Install the detector either flush to the wall or in a corner (recommended).
English Drill installation using bracket 1. Press the bracket into the motion detector. 2. Hold the motion detector next to the desired installation location and adjust to the desired angle. 3. Fix the position by tightening the screw on the rear of the bracket. 4. Stick the motion detector's drilling template in the desired installation location. Use a spirit level to ensure the drilling template is straight. Drill holes in the specified positions and insert the screw anchors provided.
English FUSG35000 siren The siren is suitable for indoor and outdoor use. For further information, please refer to the safety instructions relating to installation location and operating environment. General installation instructions Warning The tamper contact may be triggered when installing the siren. In this event, the siren is set to "LED" by default. If you have already configured the siren as "Siren" or "LED and siren", please reset this to "LED" before installation.
English FUBE35000 Remote Key The Remote Key is only suitable for indoor use. Note the information provided in the safety instructions relating to the operating environment. Installation Use the keyring to attach the Remote Key to your bunch of keys or similar.
English 4. Operation The Smartvest App is divided into two basic menus, operation and configuration. This chapter will show you how to operate the Smartvest via the Smartvest App. Please refer to chapter 5 to find out how to configure the Smartvest.
English Navigation bar and footer Open the Smartvest App and connect to the Smartvest. Navigation bar View The individual menu items are shown in the navigation bar at the top. The menu you are currently viewing is highlighted in colour. Switching menu You can switch between the individual menus by "swiping" your finger across the screen from left to right or vice versa. Alternatively, you can switch between the individual menus by tapping on the desired menu in the menu bar.
English Overview Status display Three different symbols are used to represent the different Smartvest statuses in the status display. The current status is marked in colour, with the relevant text shown below. You can change the status by dragging to the left or right or, alternatively, by tapping the desired status. Smartvest is internally armed The internal arming is pre-programmed as perimeter protection ex-works. This means that opening detectors do trigger an alarm whereas motion detectors do not.
English Hotkeys There are two pre-configured hotkeys – panic and camera – below the status display, which you can tap and enable in the overview. These two hotkeys are also found on the FUBE35000 Remote Key and can be operated from there. Standard: All actuators are triggered (e.g. sirens) and all cameras are recording Standard: All cameras are recording Note When pairing components, standard values are automatically set for the pre-configured hotkeys.
English Hotkeys Application examples Hotkeys enable straightforward activation of various components with just a tap. Should you become aware of any potential intruders outside your house before they have attempted to break in, you could, for example, configure a hotkey (panic) to activate the siren, which you could then tap to scare off the intruder before they break in.
English Rooms Room overview In the room overview, all rooms with at least one added component are shown. A maximum of two components are shown under the room name. Room details Tap the desired room to open the individual room overview. All components which have been added to the room are then listed. Tap the arrow room overview.
English 36
English Cameras Camera overview Up to four cameras can be displayed in the camera overview. In the settings (see chapter 5.5, Advanced settings), you can add four cameras in the contact overview or edit the settings for the cameras already available. You can access the live view with the various camera functions by tapping the relevant camera. TVAC19000 Live view You can control the camera by using your finger to swipe left, right, up or down across the live view.
English TVAC19100 Live view Move two fingers away from each other on the screen to zoom in on the camera image. Actions Activate microphone Tap this button to listen to the camera's recorded audio. Snapshot Tap this button to save a snapshot on your end device. Recording Press this button to start a one-minute recording. Note: Recordings are only possible if a microSD card has been inserted in the camera. The "Rec" button will not appear otherwise.
English Contacts Contact overview Up to four contacts can be displayed in the contact overview. Two pre-configured contacts – emergency and police – are already stored upon initial start-up. In the settings (see chapter 5.6, Contacts), you can add two further contacts in the contact overview or edit the contacts already available. Make calls Tapping a contact's number automatically brings up the telephone view for your end device, with the relevant contact's number predialled.
English Basic event Event overview When calling up the event list, the 100 most recent events are displayed. To view older events, use the search function. The Smartvest alarm control panel stores a maximum of 1000 entries. Note Camera events will be loaded directly from the camera into the event overview and updated. Depending on the network connection, it may take several minutes for a new video to be displayed. Note Motion detector events are not listed in the event overview.
English Alarm view Alarm view The alarm view opens when an alarm is triggered, if: the Smartvest App is already open the Smartvest App is opened after the alarm the Smartvest App is opened by tapping the alarm's push notification. Chain of events The chain of events shows you which event triggered the alarm (highlighted red), when the event triggered the alarm, and any events that have taken place since the alarm was triggered. Up to 5 events will be displayed.
English 5. Configuration The Smartvest App is divided into two basic menus, operation and configuration. This chapter will show you how to configure the Smartvest via the Smartvest App. Please refer to chapter 4 to find out how to operate the Smartvest.
English Configuration overview Configuration overview The Smartvest settings, contacts and manual are displayed in the configuration overview. Smartvest settings Enter the settings password (standard: "123456") to access all Smartvest settings options. The settings password must be entered to change the following settings: Components Hotkeys Scenarios Schedules Advanced settings These settings are described in greater detail in chapters 5.2 to 5.6.
English Components Component overview Tap "Components" to access the component overview. All paired components and the associated rooms are displayed in the overview. Pair components Tap the plus sign to add a component. Select the relevant component from the component list.
English If the pairing process was not successful, repeat the steps. Opening detector Enter a name for the component. Open the room list and select the room where the component is installed. Tap the arrow settings. Now tap "Next". Follow the instructions in the app. to return to the Note If the pairing process was not successful, tap "Pair", open the magnetic contact's battery compartment and then close it again. Motion detectors Enter a name for the component.
English Note If the pairing process was not successful, tap "Pair", loosen the smoke alarm/heat detector from the base plate, remove and replace the batteries. Siren Enter a name for the component. Open the room list and select the room where the component is installed. Tap the arrow settings. to return to the Now tap "Next". Follow the instructions in the app and then complete the process.
English Configure components Select the components you want to configure from the component overview. Alarm panel Name Enter a name for the Smartvest. Background LED Adjust the brightness of the background LED to "Off", "Low" or "High". Volume Adjust the alarm panel's volume to "Off", "Low" or "High" for alarming or other events. Off Low: 70 dB High: 90 dB Duration of the reaction Set the alarm duration for the alarm control panel in the event of an alarm.
English Opening detector Name Enter a name for the component. Room Open the room list and select the room where the opening detector is installed. Tap the arrow to return to the settings. Motion detectors Name Enter a name for the component. Room Open the room list and select the room where the motion detector is installed. Tap the arrow to return to the settings. Smoke alarm/heat detector Name Enter a name for the component. Room Open the room list and select the room where the component is installed.
English Enter a name for the component. Type of reaction Here you can set how the siren reacts when it is activated. LED LEDs flashing Siren Siren is activated LED and siren LEDs are flashing and siren is activated Duration Here you can set how long the siren sounds and how long the LEDs flash when activated. Volume Set the siren volume. Off Low: approx. 80 dB High: approx. 100 dB Attention Always maintain a distance of 3 m when the volume is set to 100 dB in order to prevent physical injury (e.g.
English Camera Name Enter a name for the component. DID Read the camera's DID number here. Security code Entering the camera's security code Advanced settings Open the advanced settings by entering the camera's admin code (default setting: 123456). Room Open the room list and select the room where the camera is installed. Tap the arrow to return to the settings.
English Adjusting for poor light conditions If light conditions are poor in night mode, adjust the video image using the 5 levels. Level 5 brightens the image as far as possible. Image alignment Here you can rotate, mirror, or rotate and mirror the image. WiFi settings Select the required network that will be used for the camera to access the Internet and enter the correct WLAN password. Note: To prevent unauthorised persons from accessing the network, protect it using WPA/ WPA2/ WPA2-PSK encryption.
English If this function is activated, the newest recordings overwrite the oldest ones once the SD card is full. Device information Here you can read the firmware version, as well as the total storage and available storage space. Hotkeys Hotkeys Tap the configured hotkeys (panic or camera) or one of the nine configurable hotkeys in order to configure these. Configured hotkeys are separated from non-configured hotkeys by a blank line.
English Scenarios Application examples Scenarios allow you to automate certain actions in your home; for example, you can use a motion detector when a room is entered or a magnetic contact when a door is opened to switch on a light source connected to a power switch. You could also use a motion detector or magnetic contact to start a camera recording, which allows you to always have an overview of who has entered your house and when.
English Schedules Application examples Schedules allow you to automate certain actions in your home as well as providing presence simulation. You can store schedules for each power switch to activate light sources that are connected to a power switch and simulate a presence when you are away, while on holiday for example. You could also connect your Christmas lights to a power switch and activate these at night-time only using a schedule.
English Advanced settings Network settings The Smartvest is set to DHCP by default. This means that the Smartvest is automatically assigned an IP address, subnet mask, gateway and DNS server by your router. Should you wish to enter these manually, switch DHCP to "Off" and enter your own details. Note We recommend leaving the DHCP function set to "On". IP address For the IP addresses available for the Smartvest IP address, refer to your router settings.
English Security settings In the security settings, you can change the security code and password for the Smartvest settings. It is strongly recommended that you change both passwords when performing the initial setup. Device security code Enter the old security code followed by the new one. Confirm this again, then tap "Save". Note The security code is automatically changed in the end device central settings where the change was carried out.
English Part set Select the actuators and sensors you would like to trigger and/or detect in "Part set" status. Exit delay Activate the exit delay so you have enough time to leave the house after arming the Smartvest. The exit delay applies for both "Active" and "Part set". Note In "Part set" status, all actuators and sensors are activated as standard, with the exception of motion detectors.
English Enable SMS notification Enable SMS notification in order to be notified on your end device when there is a status change or an alarm. For SMS notification, go to www.smstrade.de and order a subscription that suits you. After registering, you will receive a verification request on your mobile. Confirm this, then enter the key and your telephone number and select the desired program.
English Special mode Maintenance mode Set the system to maintenance mode to avoid triggering the tamper alarm and a supervision fault when changing the battery. Attention Do not forget to deactivate maintenance mode again for normal operation. Test mode After activating test mode, a view appears showing all new events including motion detection. Test mode is only available if the system is disarmed. Attention Do not forget to deactivate test mode again for normal operation.
English 6. Technical data FUAA35000 – Smartvest Model number Battery 6 x AA (2 x 3) (1.5 V) as a backup power supply Battery life h Ø5 Operating temperature °C 0–40 MHz 868,3 g 540 Frequency Weight Hygrometer Dimensions integrated mm 279.6 x 89.3 x 193.8 Max. wireless zones Max. humidity 32 % 80 Installation Network connector Free-standing or wall installation Mbit 10/100 Range m approx.
English FUMK35000 – magnetic contact Model number Battery 1 x CR2032 (3V) Battery life h Ø 1 year Operating temperature °C 0–40 MHz 868,3 g 30 mm 40 x 71 x 14 % 80 Frequency Weight Dimensions Max. humidity Installation Range Door or window installation m approx. 30 depending on the local conditions Tamper monitoring Yes Signal check Yes, time interval 3 h FUBW35000 – PIR Motion Detector Model number Battery 3 x AA (1.
English FURM35000 – smoke alarm/heat detector Model number Alarm muting m 10 Battery 2 x AA (1.5 V) Battery life h Ø 1 year Operating temperature °C 0–45 Detection range m² 40 MHz 868,3 g 166 mm 32 x 120 % 93 Frequency Weight Dimensions Max. humidity Installation Range Ceiling installation m approx. 30 depending on the local conditions Signal check Yes, time interval 3 h Model number FUSG35000 – siren Battery 4 x C (1.
English Battery 1 x CR2032 (3V) Battery life h Ø 2 years Operating temperature °C 0–40 MHz 868,3 g 22 mm 30 x 60 x 14 % 80 Frequency Weight Dimensions Max. humidity Installation Range Door or window installation m approx.