Technical data
RM04_Li_VdS_Funk 25.03.2009 14:40 Uhr Seite 14
Probedruck
C M Y CM MY CY CMY K
14
We recommend using the following high-quality alkaline batteries:
Duracell # MN 1604, Energizer Ultra+, Energizer Industrial, Varta Longlife
or a corresponding lithium battery.
Used batteries do not belong in household garbage – please dispose of
them environmentally correctly!
Replacing the battery
If the battery should be weak, the smoke detector will emit a beeping
sound once per minute (for approx. 30 days) as a reminder to replace
the battery (battery charge condition-warning). When hearing this
signal the battery must be changed for your own safety immediately.
The smoke detector remains fully functional during this period
.
• The detector automatically carries out a recalibration and self-test after battery
replacement; that is, the detector registers light contamination to itself,
but its smoke sensitivity remains identical. A longer beep sounds after this
process.
Alarm and Error Signal
• If the alarm threshold is exceeded, a clamorous alarm sounds. The alarm
remains activated for as long as smoke is found in the detection chamber.
The alarm is not turned off until the measurement chamber is smoke-free.
• This device creates two different alarm tones, to differentiate WHERE and
by WHICH device an alarm is triggered. The triggering alarm (primary alarm)
is significantly different from all other alarm sounds (secondary alarm).
• The alarm can be deactivated
– By pressing the test button (front) on one of the secondary detectors;
only this device is deactivated.
– Or by pressing the test button on the primary detector;
after a delay of approx. 20 sec., all alarm tones are deactivated.
• If the smoke detector should have a technical fault, then this will be indicated
by 2 or 3 short tones.
• Technical faults can be caused by dust, external electromagnetic faults or
extremely bright light sources. Please clean the detector as described under
the item “Maintenance”.
• If the error is not resolved by cleaning or a change of position,
please contact the vendor.