WELCOME Thank you for choosing AC Infinity. We are committed to product quality and friendly customer service. If you have any questions or suggestions, please don’t hesitate to contact us. Visit www.acinfinity.com and click contact for our contact information. EMAIL support@acinfinity.com WEB www.acinfinity.
MANUAL CODE AF2103X1 PRODUCT AIRFRAME T7 AIRFRAME T7 AIRFRAME T7-N AIRFRAME T7-N AIRFRAME T9 AIRFRAME T9 AIRFRAME T9-N AIRFRAME T9-N 4 MODEL AC-AFT7-BE AC-AFT7-WE AC-AFT7-BN AC-AFT7-WN AC-AFT9-BE AC-AFT9-WE AC-AFT9-BN AC-AFT9-WN UPC-A 819137020153 819137020160 819137020177 819137020184 854759004068 854759004549 854759004372 854759004389
MANUAL INDEX Company Contact ............................................................ Page 3 Manual Index ................................................................... Page 5 Closet Cooling Guide ....................................................... Page 6 Key Features ................................................................... Page 7 Product Contents ............................................................. Page 8 Installation ........................................................
CABINET COOLING GUIDE INTAKE AND EXHAUST All cabinet fan systems should contain an intake and an exhaust variable which can either be fans or ventilation holes. This is required to balance the static pressures between the inside and outside room. FAN POSITIONING Due to natural convection, warmer air, which is less dense than colder air, will rise on its own.
KEY FEATURES ALUMINIUM FRAME Features an aluminium frame with CNC machined corners and edges to give rooms a professional appearance. SMART CONTROLLER Controller enables temp. monitoring, thermal control, speed control, alarms, and SMART energy mode. DETACHABLE FILTER A high density filter helps remove dust from entering or exiting the room. Can be easily detached for cleaning. THERMAL PROBE The corded sensor probe constructed of stainless steel ensures an accurate temperature reading.
PRODUCT CONTENTS T-SERIES COOLING FAN UNIT (x1) PLASTIC STENCIL (x1) 8 DETACHABLE FILTER (x1) (May be on Fan Unit) THERMAL PROBE (x1) WOOD MOUNTING SCREW SET (x4) POWER ADAPTER (x1)
INSTALLATION STEP 1 Determine where you wish to mount the cooling fan unit onto your door or wall. Position the stencils and apply tape to the outer edges. STEP 2 Use a pencil to outline the center square and four outer screw holes on the one stencil. Check for accuracy before proceeding to the next step.
INSTALLATION STEP 3 Remove the plastic stencil and tape. If you prefer machine screws instead of wood screws to mount the fan and controller, use a power drill to create four screw holes. Recommended drill bit size around 16/64”. STEP 4 Using a saw, cut out the center piece as outlined by your markings from step one. You may need to first drill a hole at each of the corners to fit your saw through. A power jigsaw may be preferred for thicker wood.
INSTALLATION STEP 5 Place the fan unit into the newly cut square so that each screw hole is properly aligned. Please make sure that the cut center hole is large enough that the plastic backside of the fan does not come into contact with the cabinet. This is to minimize vibrations which will can cause noise. STEP 6 Using the four machine screws, secure the fan unit’s frame onto the cabinet or wall. Push each screw through their corresponding hole located on the frame and wall.
INSTALLATION STEP 7 After mounting the fan unit onto a door or wall, locate the filter piece. If it has not yet been installed, align and insert the filter piece into the docking holes located on the backside of the fan unit. STEP 8 Push the filter piece against the back of the fan unit to click it into position. Please note that using the detachable filter will reduce air performance of the cooling fan unit.
INSTALLATION STEP 9 To power the fan unit, locate the corded wall adapter. Plug the adapter’s connector into the port marked “POWER” located on the backside of the fan unit. STEP 10 Plug the adapter head into a standard outlet or power strip.and check to see if the fan's unit screen is on. You may need to press the leaf button if the unit was previously set to ECO Mode.
INSTALLATION STEP 11 To set up temperature readings, locate the corded thermal probe. Plug the probe’s connector into the port marked “PROBE” located on the backside of the fan unit. STEP 12 After plugging in the probe, check the fan unit’s screen to see that there is now a temperature reading. Position the thermal probe near your devices with the highest temperatures.
FILTER MAINTENANCE STEP 1 To detach the filter piece, pull on its lever to release it from the backside of the fan unit. The filter should be cleaned periodically to avoid decreasing the fan’s airflow performance. STEP 2 Rinse the filter piece with running water or wipe it down with a damp cloth to remove dust and other particles.
FILTER MAINTENANCE STEP 3 Wipe down the filter piece thoroughly with a cloth and leave it out to dry. The filter piece should be completely dry before reattaching it to the fan unit. STEP 4 Lastly, push the filter piece against the back of the fan unit to put it back into position.
CONNECTING MORE FANS Each T-Series fan unit includes a port marked “EXT.” on its backside that enables it to connect one S-series fan unit to share the same smart controls and power source. FAN EXTENSIONS S-Series fan units connected to the T-Series will share the same fan speed and temperature trigger settings. For example, an AIRFRAME T7 exhaust system can control an AIRFRAME T7-N system for intake. If the S-Series fan contains an inline speed controller, please make sure their speed is set on high.
PROGRAMMING 1. MODE BUTTON Cycles through the modes: AUTO, SMART, SPEED, ALARM, BUFFER. Holding for three seconds will lock or unlock the display. SETTING 1 3. LEAF BUTTON This turns the display off while programs run in the background. Holding will change degrees to Fahrenheit or Celsius. 2. UP / DOWN BUTTON The up and down buttons changes the setting temp, alarm temp, display brightness, or the speed of the fan. PROBE o 6 4 F 5 ALARM SPEED o F 7 o F 8 BUFFER o F 2 3 AUTO 9 18 4.
PROGRAMMING QUICK START Press the MODE button until you are on AUTO mode. This mode works like a thermostat. Press the up and down triangle buttons to change the SETTING temperature on the screen. The PROBE temperature is what the thermal probe is measuring. When the PROBE temperature exceeds the SETTING temperature, the fans will start running. SPEED SETTING In this mode, the fans will run non-stop regardless of temperature.
PROGRAMMING BUFFER SETTING In AUTO mode, a buffer is built in to prevent your fan from turning on and off too quickly due to small variations in the environment. In SMART mode, there is a range of temperatures between each speed. You can increase or decrease this buffer or range by pressing the up and down buttons. SETTING PROBE o SETTING F ALARM PROBE o SPEED o F o F BUFFER oo F F BFR SMART MODE This is the energy saving mode where the fans will change speed depending on the temperature.
PROGRAMMING ALARM SETTING In this mode, you can set what temperature the system’s alarm will trigger by pressing the up and down triangle buttons. When the PROBE temperature reaches or exceeds the ALARM temperature, the alarm will activate. The alarm will only activate while the controller is in ON, AUTO, or SMART Mode so please remember to exit ALARM Mode once the alarm has been set.
PROGRAMMING FAHRENHEIT OR CELSIUS The temperatures displayed can be set to Fahrenheit or Celsius scale by holding the LEAF button until °F or °C is shown after the digits. All digits displayed will be automatically converted to the designated scale. DISPLAY BRIGHTNESS To adjust the brightness of the display, hold down the MODE button while pressing the up button repeatedly to increase the brightness. Hold down the MODE button while pressing the down button repeatedly to decrease the brightness.
PROGRAMMING ALERT ICONS On the bottom right of the display there are three alert icons. They are visible to show that the system’s functions are being monitored. They will flash when the controller wishes to alert you that a particular function is being triggered. SETTING PROBE o F ALARM SPEED o F o F BUFFER o F SMART CHECK FAN ALERT This icon will flash when the fan’s sensor detects interference to its operation. Please check the fan for possible issues.
AC INFINITY PRODUCTS AIRCOM SERIES The AIRCOM component fan system cools receivers, amplifiers, and other AV components. S-Series models feature a thermal trigger and speed control. T-Series features a LCD digital display with thermal and speed control, alarm alerts, failure triggers, and backup memory. PRODUCT AIRCOM S6 AIRCOM S7 AIRCOM S8 AIRCOM S9 AIRCOM T8 AIRCOM T9 MODEL AI-ACS6 AI-ACS7 AI-ACS8 AI-ACS9 AI-ACT8 AI-ACT9 DIMENSIONS 11.6 x 6.3 x 1.5 in. 11.6 x 6.3 x 1.5 in. 17 x 13.5 x 1.5 in. 17 x 13.
This warranty program is our commitment to you, the product sold by AC Infinity will be free from defects in manufacturing for a period of two years from the date of purchase. If a product is found to have a defect in material or workmanship, we will take the appropriate actions defined in this warranty to resolve any issues. The warranty program applies to any order, purchase, receipt, or use of any products sold by AC Infinity or our authorized dealerships.
COPYRIGHT © 2021 AC INFINITY INC. ALL RIGHTS RESERVED No part of the materials including graphics or logos available in this booklet may be copied, photocopied, reproduced, translated or reduced to any electronic medium or machine readable form, in whole or in part, without specific permission from AC Infinity Inc.
www.acinfinity.