User Manual

T-SERIES CONTROLLER
PROGRAMMING
QUICK START
Press the MODE button until you are on AUTO mode. This mode works like a thermostat. Then
press the up and down triangle buttons to change the SETTING temperature on the screen. The
PROBE temperature is what the thermal probe is measuring. When the PROBE temperature
exceeds the SETTING temperature, the fans will start running.
ON MODE
In this mode, the fans will run non-stop regardless
of temperature. Pressing the up and down buttons
while in this mode will change the speed of the fan.
Whichever speed is designated in this mode will
also be the speed used in AUTO Mode and the
max speed of the fans in SMART Mode.
AUTO MODE
This is the thermostat setting where the fans will
start running when the PROBE temperature
reaches or surpasses the SETTING temperature.
The SETTING temperature can be designated by
pressing the up and down buttons while in this
mode. Once the fans start running, the PROBE
temperature would need to fall at least 4° F below
the SETTING temp for the fans to stop running.
This variation buffer can be changed to 2° F.
See page 21 for more information.