CLOUDLINE MIXED FLOW INLINE FAN SYSTEMS USER MANUAL
WELCOME Thank you for choosing AC Infinity. We are committed to product quality and friendly customer service. If you have any questions or suggestions, please don’t hesitate to contact us. Visit www.acinfinity.com and click contact for our contact information. EMAIL WEB LOCATION support@acinfinity.com www.acinfinity.
MANUAL CODE CL2101X1 PRODUCT MODEL UPC-A CLOUDLINE S4 CLOUDLINE S6 CLOUDLINE S8 CLOUDLINE S10 CLOUDLINE S12 CLOUDLINE T4 CLOUDLINE T6 CLOUDLINE T8 CLOUDLINE T10 CLOUDLINE T12 AI-CLS4 AI-CLS6 AI-CLS8 AI-CLS10 AI-CLS12 AI-CLT4 AI-CLT6 AI-CLT8 AI-CLT10 AI-CLT12 819137020290 819137020306 819137020849 819137020856 819137021006 854759004785 854759004792 819137020276 819137020283 819137021013 EC models CANNOT be daisy chained with DC models.
MANUAL INDEX Manual Index ................................................................................. Page 5 Key Features ................................................................................. Page 6 Product Contents ........................................................................... Page 7 Installation (Mounting) ................................................................... Page 9 Installation (Configuration Setup) ..................................................
KEY FEATURES 6 QUIET PWM MOTOR STATOR BLADE FANS SMART CONTROLLER PWM-controlled motor features precise speed control, reduced rotor noise, and energy-efficient EC voltage. Hydro-mechanical stator blades enable efficient airflow delivery in high static pressure environments. Controls and monitors temp. and humidity using included probe. Also features high temp. triggers and alarms.
PRODUCT CONTENTS CLOUDLINE S-Series SPEED CONTROLLER (x1) MACHINE SCREWS (WALL MOUNT) (x2) WOOD SCREWS (WALL MOUNT) (x2) CLOUDLINE T-Series SMART CONTROLLER (x1) SENSOR PROBE (x1) MACHINE SCREWS (WALL MOUNT) (x2) WOOD SCREWS (WALL MOUNT) (x2) WOOD SCREWS (WALL HANG) (x2) FAN UNIT (Included in both S-Series and T-Series) DUCT FAN SYSTEM (x1) DUCT CLAMP (x2) WIRE TIE (x6) CABLE TIE MOUNT (x6) WALL ANCHOR (x4) WOOD SCREWS (x6) DUCT FAN SCREW SET (x4) 7
PRODUCT CONTENTS 8
INSTALLATION MOUNTING STEP 1 Unscrew and loosen the metal rings using a Phillips screwdriver and pliers. STEP 2 Remove the motor box from the flange bracket. Remove the wind circle between the motor box and the intake flange.
INSTALLATION MOUNTING STEP 3 Use the flange bracket to set your desired fan position. Mark the four mounting holes. STEP 4 Drill four holes into the marked locations. Make sure your mounting area is structurally sound and free from obstruction.
INSTALLATION MOUNTING STEP 5 If you are mounting onto anything other than a wood support or stud, insert the included four wall anchors into the drilled mounting holes. You may need to use a hammer to secure them through the holes. STEP 6 Align the flange bracket’s holes with the wall anchors. Screw in four wood screws with a screwdriver or drill to secure the flange bracket. Make sure its airflow arrow is pointing in your desired direction.
INSTALLATION MOUNTING STEP 7 Place the wind circle back into the intake flange and reposition the metal clamps over the flanges if applicable. STEP 8 Slide the motor box back into the flange bracket, making sure its airflow arrow is pointing in the same direction as the flange bracket’s arrow. Tighten the metal clamps using a Phillips screwdriver and pliers to secure the motor box.
INSTALLATION MOUNTING STEP 9 Place the metal rings back onto the flanges and tighten the screws back to secure the fan. STEP 10 If installing ducting, use the included duct clamps to secure it to either end of the duct fan, making sure there is a tight seal. Tighten the duct clamps using a flathead screwdriver.
INSTALLATION CONFIGURATION SET-UP STEP 11(a) - Hanging Upward If installing with rope hangers (sold separately), loop the ropes around the flanges and tighten the rope to secure the fan. STEP 11(b) - Hanging Downward You may also use the bracket holes to cable manage wires or loop rope hangers to hang the fan. Make sure the fan's airflow arrow is pointing towards your desired direction.
INSTALLATION CONFIGURATION SET-UP Intake and Exhaust This fan can be used as either an intake fan or an exhaust fan in grow rooms and larger grow tents. To achieve optimal whole space ventilation, the intake fan or opening - if not using a fan - must be situated at a bottom corner of your grow space. The exhaust fan must be hung (shown below) or mounted at the highest opposite corner possible.
POWERING AND SETUP S-SERIES STEP 1 Plug the duct fan’s 4-pin molex connector into the speed controller’s port at the top. STEP 2 Lastly, to power both the fan and controller, plug the fan's power cord into an AC power outlet.
POWERING AND SETUP T-SERIES STEP 1 You may cable manage the cords using tie mounts, wood screws, and zip ties included with this fan. Secure the tie mounts onto a surface using the wood screws. Loop the zip ties around the cords into the tie mounts. STEP 2 Plug the duct fan’s 4-pin molex connector into the universal controller’s left port signified by the fan/power symbol.
POWERING AND SETUP T-SERIES STEP 3 Plug the sensor probe into the controller’s 3.5mm jack. Set the probe near your plants in your grow tent for the most accurate reading. STEP 4 Lastly, to power both the fan and controller, plug the fan's power cord into an AC power outlet.
ADDING MORE FANS The smart controller for the CLOUDLINE T-Series has an additional port so that you can add an S-Series fan to power and control two fans together. Please see below for limitations. T-SERIES CONTROLLER Smart controllers for T-Series models with EC motors can support two fans of any size. The two EC-motor fans must be plugged in to an outlet to power the fans and the controller. See images below.
CLEANING STEP 1 Remove the motor box from the mounting flange. Refer to steps 1 and 2 to learn how to remove the motor box. STEP 2 Use a damp cloth to clear the impeller and fan blades of any dust and debris. Remove the wind circle in between the motor box and input flange.
CLEANING STEP 3 Clear the stator blades of any dust and debris on the opposite end. Clean the area inside the output and exhaust flanges. STEP 4 Secure the motor box onto the mounting flanges. Refer to step 7-9 to learn how to secure the motor box.
PROGRAMMING FAN SPEED ADJUSTING The controller features a single button that controls the fan speed from 0-8. Pressing the speed button increases the fan speed in one unit increments. Pressing the button at the 8 setting will set the fan speed back to 0. Fan Spee d Indicato r POWERING ON/OFF Holding the speed button for 4 seconds will turn the fan OFF. Pressing it again from OFF will turn the fan ON at its last speed setting.
PROGRAMMING 1. MODE BUTTON Cycles through the controller's temperature/humidity programming: ON, OFF, TIMER, AUTO (4 triggers), and ALARM (4 settings). 3. LEAF BUTTON Turns the screen off while programs run in the background. Hold for two seconds to lock or unlock the LCD display. 2. UP / DOWN BUTTON Adjusts the settings of the mode that you are in. Up button raises and down button lowers. Hold both to turn off triggers. 6 7 5 8 4 9 1 2 3 4. PROBE TEMP. 5. CONTROLLER MODE 6.
PROGRAMMING MODE SETTING Pressing the Mode button will cycle through the controller’s available programming modes and settings: ON Mode, OFF Mode, TIMER Mode, AUTO Mode (4 triggers), ALARM Settings (4 settings). ON MODE In this mode, the fan will run continuously regardless of temperature or humidity. Use this mode to set the fan's maximum blowing strength, ranging from 0-10, when triggers are activated. OFF MODE In this mode, the fan will not run regardless of temperature or humidity.
PROGRAMMING TRIGGER MODE: HIGH TEMPERATURE In this mode, pressing the up or down button sets the high temperature trigger. The fan will activate if the probe’s reading meets or exceeds this trigger. It will gradually ramp up until it reaches the ON Mode’s setting. If the probe’s reading falls below your trigger, the fan will turn off. We recommend turning this trigger OFF when not in use during set up by holding the up and down buttons together.
PROGRAMMING TRIGGER MODE: HIGH HUMIDITY In this mode, pressing the up or down button sets a high humidity trigger. The fan will activate if the probe’s reading meets or exceeds this trigger. It will gradually ramp up until it reaches the ON Mode’s setting. If the probe’s reading falls below your trigger, the fan will turn off. We recommend turning this trigger OFF when not in use during set up by holding the up and down buttons together.
PROGRAMMING ALARM SETTING: HIGH TEMPERATURE In this mode, pressing the up and down button sets a high temperature alarm. The alarm will sound and its icon will flash if the probe’s reading exceeds the set temperature. To activate the alarm, leave the alarm mode. The alarm will turn OFF if the probe’s reading falls below the trigger or if any button is pressed. You can also set the alarm OFF by holding the up and down buttons together. Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode.
PROGRAMMING ALARM SETTING: HIGH HUMIDITY In this mode, pressing the up and down button sets a high humidity alarm. The alarm will sound and its icon will flash if the probe’s reading exceeds the set humidity. To activate the alarm, leave the alarm mode. The alarm will turn OFF if the probe’s reading falls below the trigger or if any button is pressed. You can also set the alarm OFF by holding the up and down buttons together. Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode.
PROGRAMMING FAHRENHEIT OR CELSIUS To switch between Fahrenheit and Celsius readings, set the controller to OFF Mode. Hold the up button to switch to Fahrenheit (°F) and the down button to switch to Celsius (°C). DISPLAY BRIGHTNESS To adjust the brightness of the display, set the controller to OFF Mode, then press the up or down button to increase or decrease the brightness level. The brightness range is 1/2/3/A3.
PROGRAMMING ALERT ICONS The top left of the display shows the alert icons. Icons may flash when the controller signals an alert to tell you a particular function or alarm is being triggered. DISPLAY LOCK ALERT This icon is visible when the controller has been locked. The icon will flash to alert you that the controller is locked if you try to change the mode or settings. HUMIDITY ALARM ALERT This icon will flash when the high or low humidity alarm has been triggered.
CLOUDLINE FAQ Q: I am missing my controller. It wasn't included in my package! A: Please refer to page 7 for an image of what your controller should look like. Your controller should be neatly slotted in the box by this product manual. Q: Where is the best place to position the sensor probe? A: Place the sensor probe as close as possible to the hottest or most humid spot in your space. Q: Do I need to remove the plastic cap from the probe? A: Yes.
CLOUDLINE FAQ Q: Does the controller retain its settings after power is shut off? A: Yes. If the controller's power is cut off and is powered on afterwards, your settings will remain. Q: What is the CFM of each of the different fan speeds? A: Please refer to your CLOUDLINE model's product listing for its CFM specification. Q: I'm not getting enough airflow even after setting the fan speed to 10. What can I do? A: Bends in ducting will reduce your fan's CFM performance.
AC INFINITY PRODUCTS Register Booster Fans The AIRTAP series is a line of register booster fans designed to quietly increase airflow coming from your central heat and air conditioning systems, increasing comfort for your home. Features a thermal controller with intelligent programming that will automatically adjust airflow strength in response to heating and cooling temperatures you have set.
WARRANTY This warranty program is our commitment to you, the product sold by AC Infinity will be free from defects in manufacturing for a period of two years from the date of purchase. If a product is found to have a defect in material or workmanship, we will take the appropriate actions defined in this warranty to resolve any issues. The warranty program applies to any order, purchase, receipt, or use of any products sold by AC Infinity or our authorized dealerships.
COPYRIGHT © 2021 AC INFINITY INC. ALL RIGHTS RESERVED No part of the materials including graphics or logos available in this booklet may be copied, photocopied, reproduced, translated or reduced to any electronic medium or machine readable form, in whole or in part, without specific permission from AC Infinity Inc.
www.acinfinity.