Installation guide

Access Control by Example Installation with RS-485, AMC and Access PE | en 15
Bosch Security Systems Introductory Guide | 1.0 | 2009.10
Figure 3.5 The AMC2 connections used in the 4-room surgery example.
Connector used for... Connector used for...
S1 PSU Power input S10 Output 3 Storeroom Opener
S2 Reader
port 1
Main Ent. and Lab card
readers
S13 Tamper
contact
(to be shorted as not in
use)
S3 Input 1 Main Ent. REX S15 Input 5 Lab. REX
S4 Input 2 Main Ent. MC S16 Input 6 Lab. MC
S5 Output 1 Main Ent. Opener S17 Output 5 Lab. Opener
S7 Reader
port 2
Store and Office card
readers
S20 Input 7 Office REX
S8 Input 3 Storeroom REX S21 Input 8 Office MC
S9 Input 4 Storeroom MC S22 Output 7 Office Opener
CAUTION!
Verify that the voltage specified for your chosen reader and peripheral components
corresponds to the voltage delivered by the power supply. If not then adjust the power supply
output voltage, see Section 3.5.1 Preparatory steps on PBC-60 power supply, AMC2 and
computer, page 13
Otherwise you risk damaging both the AMC and the connected components.